» Articles » PMID: 30811509

Manual Polishing of 3D Printed Metals Produced by Laser Powder Bed Fusion Reduces Biofilm Formation

Overview
Journal PLoS One
Date 2019 Feb 28
PMID 30811509
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Certain 3D printed metals and surface finishes may be better suited for canine patient specific orthopedic implants on the basis of minimizing potential bacterial biofilm growth. Thirty disks each of titanium alloy, stainless steel, and cobalt chromium alloy were 3D printed via laser powder bed fusion. Fifteen disks of each metal were subsequently polished. After incubation with a robust biofilm-forming methicillin-resistant Staphylococcus pseudintermedius isolate, disks were rinsed and sonicated to collect biofilm bacteria. Serial dilutions were plated on blood agar, and colony forming units were counted log (ln) transformed for analysis of variance. Interference microscopy quantified surface roughness for comparison to biofilm growth. Scanning electron microscopy on both pre- and post-sonicated disks confirmed biofilm presence and subsequent removal, and visualized surface features on cleaned disks. Significantly more bacteria grew on rough versus polished metal preparations (p < 0.0001). Titanium alloy had more bacterial biofilm growth compared to cobalt chromium alloy (p = 0.0001) and stainless steel (p < 0.0001). There were no significant growth differences between cobalt chromium alloy and stainless steel (p = 0.4737). Relationships between biofilm growth and surface roughness varied: positive with the rough preparations and negative with the smooth. Polished preparations had increased variance in surface roughness compared to rough preparations, and within disk variance predominated over between disk variance for all preparations with the exception of rough cobalt chromium alloy and rough stainless steel. Using scanning electron microscopy, bacterial biofilms tended to form in crevices. Overall, manual polishing of 3D printed surfaces significantly reduced biofilm growth, with preparation-specific relationships between surface roughness and biofilm growth. These results suggest that metallic implants produced by laser powder bed fusion should be polished. Further research will elucidate the optimal surface roughness per preparation to reduce potential biofilm formation and implant associated infection.

Citing Articles

Surface Enhancement of Additively Manufactured Bone Plate Through Hybrid-Electrochemical Magnetorheological Finishing Process.

Rajput A, Kapil S, Das M 3D Print Addit Manuf. 2024; 11(3):e1380-e1393.

PMID: 39359582 PMC: 11442415. DOI: 10.1089/3dp.2023.0028.


The Interaction between Oral Bacteria and 3D Titanium Porous Surfaces Produced by Selective Laser Melting-A Narrative Review.

Dotta T, DErcole S, Iezzi G, Pedrazzi V, Galo R, Petrini M Biomimetics (Basel). 2024; 9(8).

PMID: 39194440 PMC: 11351682. DOI: 10.3390/biomimetics9080461.


Induction Heating Triggers Antibiotic Release and Synergistic Bacterial Killing on Polymer-Coated Titanium Surfaces.

Kwan J, Flannagan R, Vasquez Pena M, Heinrichs D, Holdsworth D, Gillies E Adv Healthc Mater. 2023; 12(22):e2202807.

PMID: 37053473 PMC: 11469058. DOI: 10.1002/adhm.202202807.


Human Gingival Fibroblast Attachment to Smooth Titanium Disks with Different Surface Roughnesses.

Yanagisawa N, Ikeda T, Takatsu M, Urata K, Nishio K, Tanaka H Biomimetics (Basel). 2022; 7(4).

PMID: 36278721 PMC: 9624341. DOI: 10.3390/biomimetics7040164.


The Removal of Meat Exudate and from Stainless Steel and Titanium Surfaces with Irregular and Regular Linear Topographies.

Evans A, Slate A, Akhidime I, Verran J, Kelly P, Whitehead K Int J Environ Res Public Health. 2021; 18(6).

PMID: 33808807 PMC: 8003725. DOI: 10.3390/ijerph18063198.


References
1.
Haslauer C, Springer J, Harrysson O, Loboa E, Monteiro-Riviere N, Marcellin-Little D . In vitro biocompatibility of titanium alloy discs made using direct metal fabrication. Med Eng Phys. 2010; 32(6):645-52. DOI: 10.1016/j.medengphy.2010.04.003. View

2.
Sandler N, Salmela I, Fallarero A, Rosling A, Khajeheian M, Kolakovic R . Towards fabrication of 3D printed medical devices to prevent biofilm formation. Int J Pharm. 2013; 459(1-2):62-4. DOI: 10.1016/j.ijpharm.2013.11.001. View

3.
Verwilghen D, Singh A . Fighting surgical site infections in small animals: are we getting anywhere?. Vet Clin North Am Small Anim Pract. 2014; 45(2):243-76, v. DOI: 10.1016/j.cvsm.2014.11.001. View

4.
Yoda I, Koseki H, Tomita M, Shida T, Horiuchi H, Sakoda H . Effect of surface roughness of biomaterials on Staphylococcus epidermidis adhesion. BMC Microbiol. 2014; 14:234. PMC: 4161769. DOI: 10.1186/s12866-014-0234-2. View

5.
Bollen C, Lambrechts P, Quirynen M . Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature. Dent Mater. 1997; 13(4):258-69. DOI: 10.1016/s0109-5641(97)80038-3. View