Abstract

Objectives: Although rare, incidents of broken/dislodged fragment of various angioplasty hardwares, including catheters, guidewires, angioplasty balloons, and stents, are being increasingly reported in recent years. Since these broken fragments may cause life-threatening consequences for a patient, it is vital for an interventional cardiologist to be acquainted with different retrieval techniques. Here, we are reporting our observations of several incidents of device dislodgement/fracture during cardiac interventions and their retrieval using simple balloon method.

Methods: We present a study of eight patients in whom we attempted to retrieve dislodged/fractured cath-lab hardwares during cardiac interventions, using simple balloon method. These cases include two cases of balloon, three cases of stent, and three cases of guidewire dislodgement/fracture.

Results: Fractured/dislodged cath-lab hardwares were successfully retrieved using a simple balloon method in six out of eight cases (75%), without any need of other retrieval hardwares. We observed no major complications in any patient.

Conclusions: The balloon-assisted retrieval method is a simple, safe, and cost-effective way to avoid complications of endothelial injury, myocardial infarction, emergency coronary artery bypass graft, and sudden cardiac death. This study, particularly the context of retrieval technique used in each case, will offer valuable information to fellow interventional cardiologists.

Citing Articles

Left main stenting with stent dislodgement and entrapment in the common femoral artery: a successful transcatheter stent retrieval.

Egbuche O, Mezue K, Nwokike S, Abe T, Olanipekun T, Onuorah I Am J Cardiovasc Dis. 2021; 11(3):421-428.

PMID: 34322313 PMC: 8303031.

References
1.
Patel T, Shah S, Pandya R, Sanghvi K, Fonseca K . Broken guidewire fragment: a simplified retrieval technique. Catheter Cardiovasc Interv. 2000; 51(4):483-6. DOI: 10.1002/1522-726x(200012)51:4<483::aid-ccd24>3.0.co;2-f. View

2.
Brilakis E, Best P, Elesber A, Barsness G, Lennon R, Holmes Jr D . Incidence, retrieval methods, and outcomes of stent loss during percutaneous coronary intervention: a large single-center experience. Catheter Cardiovasc Interv. 2005; 66(3):333-40. DOI: 10.1002/ccd.20449. View

3.
Kharge J, Sreekumar P, Swamy K, Bharatha A, Ramegowda R, Cholenahally Nanjappa M . Balloon-assisted retrieval of a broken stent-delivery system. Tex Heart Inst J. 2012; 39(5):644-6. PMC: 3461686. View

4.
Patil S, Agarwal A, Ramalingam R, Kumar T, Agarwal N, Manjunath C . Successful percutaneous removal of broken mitral valvuloplasty coiled tip guidewire. Cardiovasc Interv Ther. 2013; 28(4):398-402. DOI: 10.1007/s12928-013-0178-8. View

5.
Chang W, Chen J, Li Y, Tsai L, Lee C . A two-case series of entrapment of a ruptured balloon in the coronary artery: Avoidable complications and nonsurgical management. J Formos Med Assoc. 2013; 114(11):1135-9. DOI: 10.1016/j.jfma.2013.05.008. View