» Articles » PMID: 30787213

Determination of Serum Bone-specific Alkaline Phosphatase Isoenzyme Activity in Captive Asian Elephants (Elephas Maximus) Using an Agarose Gel Electrophoresis Method

Overview
Journal J Vet Med Sci
Date 2019 Feb 22
PMID 30787213
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

The bone-specific alkaline phosphatase (ALP) isoenzyme activity was measured in 51 serum samples from four captive Asian elephants (Elephas maximus) using a conventional method with wheat germ lectin precipitation and a commercial agarose gel electrophoresis (AGE) kit; the isoenzymes were designated as bone-specific ALP (BAP) and ALP isoenzyme 3 (ALP3), respectively. This study examined the suitability of the AGE kit for analyzing blood biochemistry in Asian elephants. The serum ALP3 and BAP activities were strongly positively correlated and met the evaluation criteria for agreement using Bland-Altman analysis. The results indicate that the AGE kit can be used to examine the blood biochemistry in Asian elephants instead of the conventional method.

Citing Articles

The serum activities of alkaline phosphatase isoenzymes measured using two approved methods in zoo-managed Asian elephants (Elephas maximus).

Takehana K, Adachi M, Ishikawa S, Yamagishi N J Vet Med Sci. 2022; 85(2):232-235.

PMID: 36543184 PMC: 10017284. DOI: 10.1292/jvms.22-0440.


Anthropometric and blood data on a hand-reared captive Asian elephant (Elephas maximus) calf: A retrospective case report.

Takehana K, Kitani R, Hatate K, Onomi R, Yamagishi N J Vet Med Sci. 2020; 82(7):943-947.

PMID: 32435003 PMC: 7399311. DOI: 10.1292/jvms.19-0666.

References
1.
Hittmair K, Vielgrader H . Radiographic diagnosis of lameness in African elephants (Loxodonta africana). Vet Radiol Ultrasound. 2000; 41(6):511-5. DOI: 10.1111/j.1740-8261.2000.tb01879.x. View

2.
Itoh H, Kakuta T, Genda G, Sakonju I, Takase K . Canine serum alkaline phosphatase isoenzymes detected by polyacrylamide gel disk electrophoresis. J Vet Med Sci. 2002; 64(1):35-9. DOI: 10.1292/jvms.64.35. View

3.
Critchley L, Critchley J . A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 2003; 15(2):85-91. DOI: 10.1023/a:1009982611386. View

4.
Allen M . Biochemical markers of bone metabolism in animals: uses and limitations. Vet Clin Pathol. 2003; 32(3):101-13. DOI: 10.1111/j.1939-165x.2003.tb00323.x. View

5.
Fohr B, Dunstan C, Seibel M . Clinical review 165: Markers of bone remodeling in metastatic bone disease. J Clin Endocrinol Metab. 2003; 88(11):5059-75. DOI: 10.1210/jc.2003-030910. View