Trace Voltammetric Determination of Lead at a Recycled Battery Carbon Rod Electrode

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2019 Feb 21
PMID 30781864
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Carbon rod electrodes (CREs) were obtained from recycled zinc⁻carbon batteries and were used without further modification for the measurement of trace concentrations of lead (Pb). The electrochemical behavior of Pb at these electrodes in a variety of supporting electrolytes was investigated by cyclic voltammetry. The anodic peaks obtained on the reverse scans were indicative of Pb being deposited as a thin layer on the electrode surface. The greatest signal⁻to⁻noise ratios were obtained in organic acids compared to mineral acids, and acetic acid was selected as the supporting electrolyte for further studies. Conditions were optimized, and it was possible to determine trace concentrations of Pb by differential pulse anodic stripping voltammetry. A supporting electrolyte of 4% v/v acetic acid, with a deposition potential of -1.5 V (vs. SCE) and a deposition time of 1100 s, was found to be optimum. A linear range of 2.8 µg/L to 110 µg/L was obtained, with an associated detection limit (3σ) of 2.8 µg/L. A mean recovery of 95.6% (CV=3.9%) was obtained for a tap water sample fortified with 21.3 µg/L.

Citing Articles

Screen-Printed Carbon Electrode Modified with Carbon Nanotubes and Copper Film as a Simple Tool for Determination of Trace Concentrations of Lead Ions.

Grabarczyk M, Wawruch A Membranes (Basel). 2024; 14(2).

PMID: 38392680 PMC: 10890294. DOI: 10.3390/membranes14020053.


An Electroanalytical Solution for the Determination of Pb in Progressive Hair Dyes Using the Cork-Graphite Sensor.

Barros T, de Araujo D, Lemos de Melo A, Martinez-Huitle C, Vocciante M, Ferro S Sensors (Basel). 2022; 22(4).

PMID: 35214367 PMC: 8875311. DOI: 10.3390/s22041466.

References
1.
Honeychurch K, Hawkins D, Hart J, Cowell D . Voltammetric behaviour and trace determination of copper at a mercury-free screen-printed carbon electrode. Talanta. 2008; 57(3):565-74. DOI: 10.1016/s0039-9140(02)00060-7. View

2.
Zougagh M, Garcia de Torres A, Vereda Alonso E, Cano Pavon J . Automatic on line preconcentration and determination of lead in water by ICP-AES using a TS-microcolumn. Talanta. 2008; 62(3):503-10. DOI: 10.1016/j.talanta.2003.08.033. View

3.
Hayes C, Skubala N . Is there still a problem with lead in drinking water in the European Union?. J Water Health. 2009; 7(4):569-80. DOI: 10.2166/wh.2009.110. View

4.
Honeychurch K, Al-Berezanchi S, Hart J . The voltammetric behaviour of lead at a microband screen-printed carbon electrode and its determination in acetate leachates from glazed ceramic plates. Talanta. 2011; 84(3):717-23. DOI: 10.1016/j.talanta.2011.01.073. View

5.
Ul-Haq N, Arain M, Badar N, Rasheed M, Haque Z . Drinking water: a major source of lead exposure in Karachi, Pakistan. East Mediterr Health J. 2012; 17(11):882-6. DOI: 10.26719/2011.17.11.882. View