» Articles » PMID: 30775361

Electrochemical Biochip Assays Based on Anti-idiotypic Antibodies for Rapid and Automated On-Site Detection of Low Molecular Weight Toxins

Overview
Journal Front Chem
Specialty Chemistry
Date 2019 Feb 19
PMID 30775361
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Phycotoxins and mycotoxins, such as paralytic shellfish poisoning toxins, type A trichothecenes, and aflatoxins are among the most toxic low molecular weight toxins associated with human poisoning incidents through the consumption of naturally contaminated food. Therefore, there is an utmost need for rapid and sensitive on-site detection systems. Herein, an electrochemical biochip for fast detection of saxitoxin, T-2 toxin as well as aflatoxin M1 and their corresponding congeners, respectively, using a portable and fully automated detection platform (pBDi, portable BioDetector integrated) was developed. Toxin analysis is facilitated upon the biochip via an indirect competitive immunoassay using toxin-specific antibodies combined with anti-idiotypic antibodies. The developed biochips enable detection in the low ng/mL-range within 17 min. Moreover, the assays cover a wide linear working range of 2-3 orders of magnitude above the limit of detection with an inter-chip coefficient of variation lower than 15%. The broad specificity of the employed antibodies which react with a large number of congeners within the respective toxin group allows efficient screening of contaminated samples for the presence of these low molecular weight toxins. With respect to the analysis of human urine samples, we focused here on the detection of saxitoxin, HT-2 toxin, and aflatoxin M1, all known as biomarkers of acute toxin exposure. Overall, it was proved that the developed biochip assays can be used to rapidly and reliably identify severe intoxications caused by these low molecular weight toxins.

Citing Articles

Concordance of Biochip-Based and LC-MS/MS Methods in Urine and Blood Samples in Screening for Amphetamine and Methamphetamine.

Akbaba M, Isir A Diagnostics (Basel). 2025; 15(3).

PMID: 39941199 PMC: 11816514. DOI: 10.3390/diagnostics15030269.


Development of a Quick and Highly Sensitive Amplified Luminescent Proximity Homogeneous Assay for Detection of Saxitoxin in Shellfish.

Zhao C, Zhang Z, Li J, Lu Y, Ma F, Wang Z Toxins (Basel). 2024; 16(8).

PMID: 39195751 PMC: 11360761. DOI: 10.3390/toxins16080341.


Immunochromatographic assay for T-2 toxin based on luminescent quantum dot beads.

Qie Z, Shi J, Yan W, Gao Z, Meng W, Xiao R RSC Adv. 2022; 9(66):38697-38702.

PMID: 35540212 PMC: 9076097. DOI: 10.1039/c9ra06689f.


Innovative and Highly Sensitive Detection of Enterotoxin Based on Receptor Interaction and Monoclonal Antibodies.

Neumann T, Kruger M, Weisemann J, Mahrhold S, Stern D, Dorner M Toxins (Basel). 2021; 13(4).

PMID: 33917845 PMC: 8068247. DOI: 10.3390/toxins13040266.


Current Trends and Challenges for Rapid SMART Diagnostics at Point-of-Site Testing for Marine Toxins.

Dillon M, Zaczek-Moczydlowska M, Edwards C, Turner A, Miller P, Moore H Sensors (Basel). 2021; 21(7).

PMID: 33916687 PMC: 8038394. DOI: 10.3390/s21072499.


References
1.
Llewellyn L, Dodd M, Robertson A, Ericson G, de Koning C, Negri A . Post-mortem analysis of samples from a human victim of a fatal poisoning caused by the xanthid crab, Zosimus aeneus. Toxicon. 2002; 40(10):1463-69. DOI: 10.1016/s0041-0101(02)00164-2. View

2.
Nebling E, Grunwald T, Albers J, Schafer P, Hintsche R . Electrical detection of viral DNA using ultramicroelectrode arrays. Anal Chem. 2004; 76(3):689-96. DOI: 10.1021/ac0348773. View

3.
Garcia C, Del Carmen Bravo M, Lagos M, Lagos N . Paralytic shellfish poisoning: post-mortem analysis of tissue and body fluid samples from human victims in the Patagonia fjords. Toxicon. 2004; 43(2):149-58. DOI: 10.1016/j.toxicon.2003.11.018. View

4.
Williams J, Phillips T, Jolly P, Stiles J, Jolly C, Aggarwal D . Human aflatoxicosis in developing countries: a review of toxicology, exposure, potential health consequences, and interventions. Am J Clin Nutr. 2004; 80(5):1106-22. DOI: 10.1093/ajcn/80.5.1106. View

5.
Elsholz B, Worl R, Blohm L, Albers J, Feucht H, Grunwald T . Automated detection and quantitation of bacterial RNA by using electrical microarrays. Anal Chem. 2006; 78(14):4794-802. DOI: 10.1021/ac0600914. View