Effect of CT Localizer Radiographs on Radiation Dose Associated With Automatic Tube Current Modulation: A Multivendor Study

Overview
Specialty Radiology
Date 2019 Feb 2
PMID 30704769
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: To assess the influence of the CT localizer radiograph on the automatic tube current modulation system of 7 CT scanners produced by 4 different CT manufacturers.

Methods: The influence of the localizer orientation, table height, tube current and tube potential values on the radiation dose of the related CT scan were evaluated. Images were acquired by using an anthropomorphic phantom positioned in the CT gantry isocenter as well as from -6 cm to +6 cm vertically to the isocenter.

Results: Vertical movement of the CT table height affected the radiation dose in all scanners using anterior-posterior or a posterior-anterior localizer orientation albeit differently, depending on the manufacturer; only in 1/7 scanner no influence was observed. The latero-lateral localizer orientation proved to be more effective in limiting the influence of the vertical miscentering in all scanners. Changing localizer's tube voltage influenced the scan radiation dose in scanners produced by two manufacturers, while no significant effect was observed in scanners produced by the other two manufacturers. No significant dose variation was observed in 6/7 scanners when changing the localizer's tube current.

Conclusion: Localizer radiograph shows a significant influence on the radiation exposure but with different outcomes depending on the manufacturer of the CT scanner. Radiologists and radiographers should have a thorough understanding of these differences to assure patients the best examination in terms of radiation dose and image quality.

Citing Articles

Comparing organ and effective dose of various CT localizer acquisition strategies: A Monte Carlo study.

Oostveen L, Tunissen S, Sechopoulos I Med Phys. 2024; 52(1):576-584.

PMID: 39395203 PMC: 11699993. DOI: 10.1002/mp.17447.


The Impacts of Vertical Off-Centring, Localiser Direction, Phantom Positioning and Tube Voltage on CT Number Accuracy: An Experimental Study.

Al-Hayek Y, Spuur K, Davidson R, Hayre C, Zheng X J Imaging. 2022; 8(7).

PMID: 35877619 PMC: 9316438. DOI: 10.3390/jimaging8070175.


Explore the Value of Dual Source Computer Tomography Automatic Tube Current Regulation in Reducing the Radiation Dose of CTA in Lower Extremity Vessels.

Hu X, Yu Y Front Surg. 2022; 9:896370.

PMID: 35592130 PMC: 9112657. DOI: 10.3389/fsurg.2022.896370.


Impacts of Phantom Off-Center Positioning on CT Numbers and Dose Index CTDIv: An Evaluation of Two CT Scanners from GE.

Zheng X, Gutsche L, Al-Hayek Y, Stanton J, Elshami W, Jensen K J Imaging. 2021; 7(11).

PMID: 34821866 PMC: 8625132. DOI: 10.3390/jimaging7110235.


0° vs. 180° CT localiser: The effect of vertical off-centring, phantom positioning and tube voltage on dose optimisation in multidetector computed tomography.

Al-Hayek Y, Zheng X, Davidson R, Hayre C, Al-Mousa D, Finlay C J Med Radiat Sci. 2021; 69(1):5-12.

PMID: 34402591 PMC: 8892417. DOI: 10.1002/jmrs.535.