» Articles » PMID: 30686709

Validation of In-vitro Tests of Zirconia-ceramic Inlay-retained Fixed Partial Dentures: A Finite Element Analysis

Overview
Journal Dent Mater
Specialty Dentistry
Date 2019 Jan 29
PMID 30686709
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: In the past, discrepancies between laboratory results and clinical behavior have been observed for all-ceramic restorations. This analysis of fracture resistance of zirconia-based inlay-retained fixed partial dentures (IRFPDs) aimed at identifying correlations between an in-vitro test setup and the clinical situation. The effects of tooth material, tooth mobility, restoration design, load direction, and different cements were taken into account.

Methods: The in-vitro test model and IRFPD were reverse engineered (Geomagic DesignX) and meshed predominantly with hexahedral elements (approx. 230,000 elements). Homogenous, linear-elastic behavior was assumed for all materials. On the basis of the calculated stresses (ANSYS 18.2) and already known strength distributions for the restorative materials fracture resistance of the complete restoration and force at initial damage (fracture within the veneer) was estimated on the basis of the principal stress hypothesis. Differences depending on the assumed clinical situation and effects of different variables on fracture resistance were evaluated.

Results: All variables tested in the finite element analysis affected the calculated fracture resistance of the IRFPD. Use of resin teeth led to an underestimation of fracture resistance by up to -57%, whereas fracture resistance of IRFPDs on metal abutment teeth was close to the clinical reference (-6% to +15%). Good correlation between the clinical scenario and that using metal teeth could only be achieved when the natural resilience of the abutment teeth was simulated.

Significance: When testing fracture resistance of zirconia-based IRFPDs, metal abutment teeth in combination with simulated tooth resilience can reflect the clinical situation accurately.

Citing Articles

Finite element analysis (FEA) of the stress behavior of some dental materials.

Di Francesco P, Bechir A, Popescu A, Chivu M, Dobrescu A, Comaneanu R J Med Life. 2025; 18(1):29-37.

PMID: 40071154 PMC: 11891613. DOI: 10.25122/jml-2025-0005.


Zirconia single retainer fixed dental prostheses for the posterior region-A novel preparation technique and literature review.

Andrei A, Constantin C, Tabitha A, Anca J Clin Case Rep. 2024; 12(10):e9460.

PMID: 39421529 PMC: 11483597. DOI: 10.1002/ccr3.9460.


Initial damage and failure load of zirconia-ceramic and metal-ceramic posterior cantilever fixed partial dentures.

Bomicke W, Boisseree P, Rammelsberg P, Rues S Clin Oral Investig. 2024; 28(1):94.

PMID: 38221600 PMC: 10788321. DOI: 10.1007/s00784-024-05501-z.


Fracture Resistance of Posterior Tooth-Supported Cantilever Fixed Dental Prostheses of Different Zirconia Generations and Framework Thicknesses: An In Vitro Study.

Klotz A, Halfmann J, Rues S, Bomicke W, Rammelsberg P, Zenthofer A Materials (Basel). 2024; 17(1).

PMID: 38204115 PMC: 10779861. DOI: 10.3390/ma17010263.


Effects on different full-coverage designs and materials of crack propagation in first mandibular molar: an extended finite element method study.

Ni J, Xu L, Lin Y, Lai D, Huang X Front Bioeng Biotechnol. 2023; 11:1222060.

PMID: 37650043 PMC: 10464904. DOI: 10.3389/fbioe.2023.1222060.