» Articles » PMID: 30603834

Evaluation of Coronary Artery Variations Using Dual-source Coronary Computed Tomography Angiography in Neonates with Transposition of the Great Arteries

Overview
Journal Jpn J Radiol
Publisher Springer
Specialty Radiology
Date 2019 Jan 4
PMID 30603834
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: The purpose of this study was to investigate whether the origins and courses of the coronary arteries could be better assessed using ECG-gated dual-source computed tomography (CT) than with echocardiography in neonates with transposition of the great arteries (TGA).

Methods: A total of 17 neonates within 14 days old who underwent both echocardiography and retrospective ECG-gated coronary CT angiography were retrospectively reviewed. The patients were sedated and intubated during CT examinations, and CT images were obtained with a breath-hold. CT images were reconstructed by multiple cardiac phases, and the coronary artery assessment was performed in the most static phase. Coronary anomalies were classified by Shaher's classification and validated by surgical findings.

Results: CT correctly classified 16 of 17 cases (Shaher type 1: 7, type 2: 4, type 9: 3, type 3: 1, type 4: 2), whereas echocardiography classified only 8 of 17 cases correctly. Dual-source CT had a significantly higher diagnostic ability than echocardiography (p = 0.0078).

Conclusion: Dual-source coronary CT angiography has a higher diagnostic ability than echocardiography in the assessment of the origins and courses of the coronary arteries in neonates with TGA.

Citing Articles

Prenatal diagnosis of a coronary-to-pulmonary artery fistula in a fetus with pulmonary atresia and ventricular septal defect.

Ishii R, Ishida H, Narita J, Ozono K BMJ Case Rep. 2022; 15(6).

PMID: 35732357 PMC: 9226865. DOI: 10.1136/bcr-2022-249271.


Application of prospective ECG-gated multiphase scanning for coronary CT in children with different heart rates.

Tang S, Zhang G, Chen Z, Liu X, He L Jpn J Radiol. 2021; 39(10):946-955.

PMID: 34046853 DOI: 10.1007/s11604-021-01133-5.


Third-generation dual-source dual-energy CT in pediatric congenital heart disease patients: state-of-the-art.

Schicchi N, Fogante M, Esposto Pirani P, Agliata G, Basile M, Oliva M Radiol Med. 2019; 124(12):1238-1252.

PMID: 31630332 DOI: 10.1007/s11547-019-01097-7.


Response to Evaluation of coronary artery variations using dual-source coronary computed tomography angiography in neonates with transposition of the great arteries.

Kardos M Jpn J Radiol. 2019; 38(1):93.

PMID: 31342268 DOI: 10.1007/s11604-019-00857-9.

References
1.
Samanek M, VORISKOVA M . Congenital heart disease among 815,569 children born between 1980 and 1990 and their 15-year survival: a prospective Bohemia survival study. Pediatr Cardiol. 1999; 20(6):411-7. DOI: 10.1007/s002469900502. View

2.
Samanek M . Congenital heart malformations: prevalence, severity, survival, and quality of life. Cardiol Young. 2000; 10(3):179-85. DOI: 10.1017/s1047951100009082. View

3.
Hoffman J, Kaplan S . The incidence of congenital heart disease. J Am Coll Cardiol. 2002; 39(12):1890-900. DOI: 10.1016/s0735-1097(02)01886-7. View

4.
Pasquali S, Hasselblad V, Li J, Kong D, Sanders S . Coronary artery pattern and outcome of arterial switch operation for transposition of the great arteries: a meta-analysis. Circulation. 2002; 106(20):2575-80. DOI: 10.1161/01.cir.0000036745.19310.bb. View

5.
Thomas K, Wang B . Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method. Pediatr Radiol. 2008; 38(6):645-56. DOI: 10.1007/s00247-008-0794-0. View