Background: The treatment of choice in end-stage renal disease is transplantation. Hemodynamic disturbances can evoke graft loss, while early ultrasound identification of vascular problems improves outcome. The aim of this study was to identify differences in postoperative complications with and without systematic intraoperative Doppler ultrasound use.

Methods: The primary outcome was the postoperative rate of complications and the secondary aim was to find a predictive resistance index cut-off value, which would show where surgical reintervention was necessary. Over a 10-year period, 108 renal transplants were performed from living donors at our institution. In group 1 (n = 67), intraoperative duplex ultrasound and intraparenchymatous resistance index measurements assessed patients, while in group 2 (n = 41), no ultrasound was performed.

Results: There were no intergroup differences in the overall postoperative complication rate or in benefit to graft or patient survival with Doppler use. However, significantly more vascular complications (10% vs 0%, P = .02) and more acute rejections (37% vs 10%) occurred in group 2 than in group 1. Therefore, an intraoperative cut-off value of the resistance index 0.5 was proposed to justify immediate surgical revision.

Conclusions: This is the first report demonstrating benefits of systematic intraoperative Doppler ultrasound on postoperative complications in renal transplantation from living donors. Our results support surgical revision with a resistance index <0.5.

Citing Articles

Systematic review of intra-operative duplex scanning during renal transplantation.

Thebridge L, Fisher C, Puttaswamy V, Pollock C, Clarke J Australas J Ultrasound Med. 2022; 25(1):42-50.

PMID: 35251902 PMC: 8873620. DOI: 10.1002/ajum.12289.


Artificial Intelligence Pulse Coupled Neural Network Algorithm in the Diagnosis and Treatment of Severe Sepsis Complicated with Acute Kidney Injury under Ultrasound Image.

Ying F, Chen S, Pan G, He Z J Healthc Eng. 2021; 2021:6761364.

PMID: 34336164 PMC: 8315850. DOI: 10.1155/2021/6761364.