People Undertaking Pulmonary Rehabilitation Are Willing and Able to Provide Accurate Data Via a Remote Pulse Oximetry System: a Multicentre Observational Study
Overview
Authors
Affiliations
Questions: Can people referred to pulmonary rehabilitation easily learn to use a system for remote transmission of oximetry data? Do they consider remote transmission of oximetry data to be satisfactory? Are the transmitted data valid compared with locally stored data?
Design: Multicentre, prospective, observational study.
Participants: One hundred and five adults with chronic respiratory disease who were referred to pulmonary rehabilitation.
Intervention: At an initial session, participants were taught to record and transmit their oximetry data to a remote server. At subsequent testing session(s), participants were requested to independently activate and use the oximetry monitoring system for a period of exercise on a cycle ergometer, until autonomy with the system was demonstrated. A subgroup of five participants undertook five 45-minute training sessions to generate a dataset to assess whether the transmitted data were valid compared with the locally stored data.
Outcome Measures: Outcome measures included the number of sessions needed to become autonomous, participant satisfaction with the system, and measures of the validity of the transmitted data.
Results: Participants became autonomous quickly: 86% at the first testing session and 100% within three testing sessions. At least 98% of participants agreed that the system was easy to use and they would be willing to use it throughout pulmonary rehabilitation. The system transmitted usable data from 98% (95% CI 96 to 100) of sessions and introduced minimal artefact. Mean absolute differences were 0.365 beats/minute for heart rate and 0.133% for oxyhaemoglobin saturation. For heart rate, exact agreement was 72% (SD 9) and similar agreement (within 3 beats/minute) was 99% (SD 1). For oxyhaemoglobin saturation, exact agreement was 87% (SD 3) and similar agreement (within 3%) was 100% (SD 0).
Conclusion: The telemonitoring system used in this study was sufficiently valid and acceptable for use in at-home pulmonary rehabilitation by people with chronic respiratory disease.
Study Registration: ClinicalTrials.gov NCT03295474 and NCT03004716 (subgroup study).
de Oliveira T, Pereira A, Costa G, de Souza Mendes L, de Almeida L, Velloso M Front Rehabil Sci. 2022; 3:780736.
PMID: 36188941 PMC: 9397727. DOI: 10.3389/fresc.2022.780736.
Pehlivan E, Palali I, Atan S, Turan D, Cinarka H, Cetinkaya E Ann Thorac Med. 2022; 17(2):110-117.
PMID: 35651892 PMC: 9150661. DOI: 10.4103/atm.atm_543_21.
Is Methadone Safe for Patients With Opioid Use Disorder and Coronavirus Disease 2019 Infection?.
Owiti J, Benson M, Maplanka M, Oluseye L, Carvalho D J Addict Nurs. 2022; 33(2):86-94.
PMID: 35640212 PMC: 9186399. DOI: 10.1097/JAN.0000000000000457.
Oxygen Saturation Behavior by Pulse Oximetry in Female Athletes: Breaking Myths.
Martin-Escudero P, Cabanas A, Fuentes-Ferrer M, Galindo-Canales M Biosensors (Basel). 2021; 11(10).
PMID: 34677347 PMC: 8534025. DOI: 10.3390/bios11100391.
Galbraith M, Kelso P, Levine M, Wasserman R, Sikka J, Read J Public Health Pract (Oxf). 2021; 2:100186.
PMID: 34467257 PMC: 8390119. DOI: 10.1016/j.puhip.2021.100186.