» Articles » PMID: 30532657

Tracking, Gating, Free-breathing, Which Technique to Use for Lung Stereotactic Treatments? A Dosimetric Comparison

Overview
Specialty Oncology
Date 2018 Dec 12
PMID 30532657
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The management of breath-induced tumor motion is a major challenge for lung stereotactic body radiation therapy (SBRT). Three techniques are currently available for these treatments: tracking (T), gating (G) and free-breathing (FB).

Aim: To evaluate the dosimetric differences between these three treatment techniques for lung SBRT.

Materials And Methods: Pretreatment 4DCT data were acquired for 10 patients and sorted into 10 phases of a breathing cycle, such as 0% and 50% phases defined respectively as the inhalation and exhalation maximum. GTV, PTV (=GTV + 3 mm) and the ipsilateral lung were contoured on each phase.For the tracking technique, 9 fixed fields were adjusted to each PTV for the 10 phases. The gating technique was studied with 3 exhalation phases (40%, 50% and 60%). For the free-breathing technique, ITV was created from a sum of all GTV and a 3 mm margin was added to define a PTV. Fields were adjusted to PTV and dose distributions were calculated on the average intensity projection (AIP) CT. Then, the beam arrangement with the same monitor units was planned on each CT phase.The 3 modalities were evaluated using DVHs of each GTV, the homogeneity index and the volume of the ipsilateral lung receiving 20 Gy ( ).

Results: The FB system improved the target coverage by increasing (75.87-76.08-77.49Gy). Target coverage was slightly more homogeneous, too (HI: 0.17-0.15). But the lung was better protected with the tracking system ( : 3.82-4.96-6.34%).

Conclusions: Every technique provides plans with a good target coverage and lung protection. While irradiation with free-breathing increases doses to GTV, irradiation with the tracking technique spares better the lung but can dramatically increase the treatment complexity.

Citing Articles

A novel internal target volume definition based on velocity and time of respiratory target motion for external beam radiotherapy.

Yamanaka M, Nishio T, Iwabuchi K, Nagata H Radiol Phys Technol. 2024; 17(4):843-853.

PMID: 39269608 DOI: 10.1007/s12194-024-00837-3.


Radiation therapy for ventricular arrhythmias.

Liulu X, Balaji P, Barber J, De Silva K, Murray T, Hickey A J Med Imaging Radiat Oncol. 2024; 68(8):893-913.

PMID: 38698577 PMC: 11686466. DOI: 10.1111/1754-9485.13662.


A four-dimensional dynamic conformal arc approach for real-time tumor tracking: A retrospective treatment planning study.

Yau T, Kempe J, Gaede S J Appl Clin Med Phys. 2023; 25(3):e14224.

PMID: 38146134 PMC: 10930003. DOI: 10.1002/acm2.14224.


Feasibility of fast, four-dimensional computed tomography-based O-ring LINAC plans for lung stereotactic body radiotherapy in patients with poor performance status.

Heo E, Kim M, Park C, Chang K, Kim K, Shim J Front Oncol. 2023; 13:1270677.

PMID: 38074663 PMC: 10699148. DOI: 10.3389/fonc.2023.1270677.


Online Adaptive MRI-Guided Stereotactic Body Radiotherapy for Pancreatic and Other Intra-Abdominal Cancers.

Lee D, Renz P, Oh S, Hwang M, Pavord D, Yun K Cancers (Basel). 2023; 15(21).

PMID: 37958447 PMC: 10648954. DOI: 10.3390/cancers15215272.


References
1.
Underberg R, Lagerwaard F, Slotman B, Cuijpers J, Senan S . Benefit of respiration-gated stereotactic radiotherapy for stage I lung cancer: an analysis of 4DCT datasets. Int J Radiat Oncol Biol Phys. 2005; 62(2):554-60. DOI: 10.1016/j.ijrobp.2005.01.032. View

2.
Davies G, Clowes P, Bedford J, Evans P, Webb S, Poludniowski G . An experimental evaluation of the Agility MLC for motion-compensated VMAT delivery. Phys Med Biol. 2013; 58(13):4643-57. DOI: 10.1088/0031-9155/58/13/4643. View

3.
James J, Swanson C, Lynch B, Wang B, Dunlap N . Quantification of planning target volume margin when using a robotic radiosurgery system to treat lung tumors with spine tracking. Pract Radiat Oncol. 2014; 5(4):e337-43. DOI: 10.1016/j.prro.2014.11.001. View

4.
Nagata Y, Negoro Y, Aoki T, Mizowaki T, Takayama K, Kokubo M . Clinical outcomes of 3D conformal hypofractionated single high-dose radiotherapy for one or two lung tumors using a stereotactic body frame. Int J Radiat Oncol Biol Phys. 2002; 52(4):1041-6. DOI: 10.1016/s0360-3016(01)02731-6. View

5.
Karaman K, Dokdok A, Karadeniz O, Ceylan C, Engin K . Intravascular Placement of Metallic Coils as Lung Tumor Markers for CyberKnife Stereotactic Radiation Therapy. Korean J Radiol. 2015; 16(3):626-31. PMC: 4435994. DOI: 10.3348/kjr.2015.16.3.626. View