» Articles » PMID: 30524929

Cross-transmission in the Dental Office: Does This Make You Ill?

Overview
Specialty Dentistry
Date 2018 Dec 8
PMID 30524929
Citations 48
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose Of Review: Recently, numerous scientific publications were published which shed new light on the possible risks of infection for dental healthcare workers and their patients. This review aimed to provide the latest insights in the relative risks of transmission of (pathogenic) micro-organisms in the dental office.

Recent Findings: Of all different routes of micro-organism transmission during or immediately after dental treatment (via direct contact/via blood-blood contact/via dental unit water and aerosols), evidence of transmission is available. However, the recent results put the risks in perspective; infections related to the dental office are most likely when infection control measures are not followed meticulously.

Summary: The risk for transmission of pathogens in a dental office resulting in an infectious disease is still unknown; it seems to be limited in developed countries but it cannot be considered negligible. Therefore, maintaining high standards of infection preventive measures is of high importance for dental healthcare workers to avoid infectious diseases due to cross-contamination.

Citing Articles

Periodic detection and disinfection maintenance of dental unit waterlines in dental simulation head model laboratories.

Li B, Hu Y, Wang Y, Zhang C, Wang Z, Peng X Sci Rep. 2025; 15(1):5234.

PMID: 39939661 PMC: 11821815. DOI: 10.1038/s41598-025-89010-3.


Degree of Contamination of Gutta-Percha Points by (MRSA/MSSA) Strains.

Teles A, Pina C, Cardoso I, Tramontana A, Cardoso M, Duarte A Int J Mol Sci. 2024; 25(16).

PMID: 39201252 PMC: 11354985. DOI: 10.3390/ijms25168566.


Detection of viable oral bacteria of the patient on the surgical mask of dentists.

Gund M, Naim J, Lang J, Hannig M, Gartner B, Halfmann A BDJ Open. 2024; 10(1):4.

PMID: 38228600 PMC: 10791691. DOI: 10.1038/s41405-023-00182-4.


Effect of herbal mouthrinsein dental ultrasonic scalers among Indians.

Agrawal A, Keerthipati S, Sreerama S, Singla D, Acharya S, Mehta D Bioinformation. 2023; 19(11):1104-1110.

PMID: 38046514 PMC: 10692984. DOI: 10.6026/973206300191104.


Efficacy and design requirements of UV light cabinets for disinfection of exchangeable non-sterilizable "dental objects".

Moufti M, Hamad M, Al Shawa A, Mardini A, Ghebeh S Sci Rep. 2023; 13(1):19755.

PMID: 37957167 PMC: 10643671. DOI: 10.1038/s41598-023-45481-w.


References
1.
Walia S, Manchanda A, Narang R, N A, Singh B, Kahlon S . Cellular telephone as reservoir of bacterial contamination: myth or fact. J Clin Diagn Res. 2014; 8(1):50-3. PMC: 3939586. DOI: 10.7860/JCDR/2014/6398.3948. View

2.
Almatroudi A, Hu H, Deva A, Gosbell I, Jacombs A, Jensen S . A new dry-surface biofilm model: An essential tool for efficacy testing of hospital surface decontamination procedures. J Microbiol Methods. 2015; 117:171-6. DOI: 10.1016/j.mimet.2015.08.003. View

3.
Reinthaler F, Mascher F, Stunzner D . Serological examinations for antibodies against Legionella species in dental personnel. J Dent Res. 1988; 67(6):942-3. DOI: 10.1177/00220345880670061001. View

4.
Johani K, Abualsaud D, Costa D, Hu H, Whiteley G, Deva A . Characterization of microbial community composition, antimicrobial resistance and biofilm on intensive care surfaces. J Infect Public Health. 2017; 11(3):418-424. DOI: 10.1016/j.jiph.2017.10.005. View

5.
Baek Y, Baek S, Yoo Y . Higher nasal carriage rate of methicillin-resistant Staphylococcus aureus among dental students who have clinical experience. J Am Dent Assoc. 2016; 147(5):348-53. DOI: 10.1016/j.adaj.2015.12.004. View