» Articles » PMID: 30480387

Beating Heart Porcine High-fidelity Simulator for the Training of Edge-to-edge Mitral Valve Repair

Overview
Date 2018 Nov 28
PMID 30480387
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Transcatheter treatment of structural heart disease is becoming an everyday reality for an increasing number of surgeons, and effective training modalities for basic guide-wire skills, catheter handling, and periprocedural imaging are of growing relevance. In this video tutorial we present a beating-heart porcine model used as a high-fidelity training simulator for transcatheter cardiac valve procedures.  We demonstrate a complete transcatheter edge-to-edge mitral valve repair procedure, including periprocedural imaging, clip deployment, and quality control. Various mitral valve pathologies can be simulated, including the demonstrated leaflet prolapse. Trainees practice clip navigation within the left atrium, transmitral passage, and clip orientation as well as grasping mitral valve leaflets to treat mitral regurgitation.  Periprocedural imaging is achieved via epicardial echocardiography and left ventricular cardioscopy, and these imaging modalities are also relied on to guide surgeons during the simulations, as required. The beating heart model enables realistic demonstration of the hemodynamic consequences of valve repair, and we believe that this simulator represents a valuable adjunct to surgical training.

Citing Articles

Congenital cardiac surgical simulation: bridging global workforce gaps and optimizing outcomes.

Deng M, Vervoort D, Valverde I, Yoo S, Peel B, Vanderlaan R Future Cardiol. 2025; 21(2):123-129.

PMID: 39862146 PMC: 11812351. DOI: 10.1080/14796678.2025.2458402.


The evolution of technical prerequisites and local boundary conditions for optimization of mitral valve interventions-Emphasis on skills development and institutional risk performance.

Cocchieri R, van de Wetering B, Baan Jr J, Driessen A, Riezebos R, van Tuijl S Front Cardiovasc Med. 2023; 10:1101337.

PMID: 37547244 PMC: 10402900. DOI: 10.3389/fcvm.2023.1101337.


At the Crossroads of Minimally Invasive Mitral Valve Surgery-Benching Single Hospital Experience to a National Registry: A Plea for Risk Management Technology.

Cocchieri R, van de Wetering B, van Tuijl S, Mousavi I, Riezebos R, de Mol B J Cardiovasc Dev Dis. 2022; 9(8).

PMID: 36005425 PMC: 9410306. DOI: 10.3390/jcdd9080261.


A Review of Human Circulatory System Simulation: Bridging the Gap between Engineering and Medicine.

Mahmoud A, Alsalemi A, Bensaali F, Ait Hssain A, Hassan I Membranes (Basel). 2021; 11(10).

PMID: 34677510 PMC: 8537247. DOI: 10.3390/membranes11100744.