Improvement of Electrospray Stability in Negative Ion Mode for Nano-PGC-LC-MS Glycoanalysis Via Post-column Make-up Flow

Overview
Journal Glycoconj J
Publisher Springer
Date 2018 Nov 24
PMID 30467791
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Analysis of glycans via a porous graphitized carbon liquid chromatography (PGC-LC) coupled with electrospray ionization (tandem) mass spectrometry (ESI-MS(/MS)) is a powerful analytical method in the field of glycomics. Isobaric glycan structures can be identified reliably with the help of PGC-LC separation and subsequent identification by ESI-MS(/MS) in negative ion mode. In an effort to adapt PGC-LC-ESI-MS(/MS) to the nano-scale operation, spray instability along the nano-PGC-LC gradient was repeatedly observed on an LTQ Orbitrap Elite mass spectrometer equipped with a standard nano-electrospray ionization source. A stable electrospray was achieved with the implementation of a post-column make-up flow (PCMF). Thereby, acetonitrile was used to supplement the eluate from the nano-PGC-LC column. The improved spray stability enhanced detection and resolution of glycans during the analysis. This was in particular the case for smaller O-glycans which elute early in the high aqueous content regime of the nano-PGC-LC elution gradient. This study introduces PCMF as an easy-to-use instrumental adaptation to significantly improve spray stability in negative ion mode nano-PGC-LC-ESI-MS(/MS)-based analysis of glycans.

Citing Articles

Multinozzle Emitter for Improved Negative Mode Analysis of Reduced Native -Glycans by Microflow Porous Graphitized Carbon Liquid Chromatography Mass Spectrometry.

Wojtkiewicz M, Subramanian S, Gundry R Anal Chem. 2024; 96(15):5746-5751.

PMID: 38556995 PMC: 11024887. DOI: 10.1021/acs.analchem.3c03649.


Systematic Investigation of LC Miniaturization to Increase Sensitivity in Wide-Target LC-MS-Based Trace Bioanalysis of Small Molecules.

Fitz V, Abiead Y, Berger D, Koellensperger G Front Mol Biosci. 2022; 9:857505.

PMID: 35923463 PMC: 9340153. DOI: 10.3389/fmolb.2022.857505.


In-House Packed Porous Graphitic Carbon Columns for Liquid Chromatography-Mass Spectrometry Analysis of Glycans.

Young C, Condina M, Briggs M, Moh E, Kaur G, Oehler M Front Chem. 2021; 9:653959.

PMID: 34178940 PMC: 8226321. DOI: 10.3389/fchem.2021.653959.


State-of-the-Art Glycomics Technologies in Glycobiotechnology.

Pralow A, Cajic S, Alagesan K, Kolarich D, Rapp E Adv Biochem Eng Biotechnol. 2020; 175:379-411.

PMID: 33112988 DOI: 10.1007/10_2020_143.


Nano-liquid chromatography-mass spectrometry and recent applications in omics investigations.

Sanders K, Edwards J Anal Methods. 2020; 12(36):4404-4417.

PMID: 32901622 PMC: 7530103. DOI: 10.1039/d0ay01194k.

References
1.
Thiesler C, Cajic S, Hoffmann D, Thiel C, van Diepen L, Hennig R . Glycomic Characterization of Induced Pluripotent Stem Cells Derived from a Patient Suffering from Phosphomannomutase 2 Congenital Disorder of Glycosylation (PMM2-CDG). Mol Cell Proteomics. 2016; 15(4):1435-52. PMC: 4824866. DOI: 10.1074/mcp.M115.054122. View

2.
Aich U, Lakbub J, Liu A . State-of-the-art technologies for rapid and high-throughput sample preparation and analysis of N-glycans from antibodies. Electrophoresis. 2016; 37(11):1468-88. DOI: 10.1002/elps.201500551. View

3.
Kawasaki N, Ohta M, Hyuga S, Hyuga M, Hayakawa T . Application of liquid chromatography/mass spectrometry and liquid chromatography with tandem mass spectrometry to the analysis of the site-specific carbohydrate heterogeneity in erythropoietin. Anal Biochem. 2000; 285(1):82-91. DOI: 10.1006/abio.2000.4739. View

4.
Schmidt A, Karas M, Dulcks T . Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: when does ESI turn into nano-ESI?. J Am Soc Mass Spectrom. 2003; 14(5):492-500. DOI: 10.1016/S1044-0305(03)00128-4. View

5.
Varki A . Biological roles of oligosaccharides: all of the theories are correct. Glycobiology. 1993; 3(2):97-130. PMC: 7108619. DOI: 10.1093/glycob/3.2.97. View