Patient Motion Correction for Dynamic Cardiac PET: Current Status and Challenges

Overview
Journal J Nucl Cardiol
Date 2018 Nov 14
PMID 30421380
Citations 5
Authors
Affiliations
Soon will be listed here.
Citing Articles

Inter-Software Reproducibility of Quantitative Values of Myocardial Blood Flow and Coronary Flow Reserve Acquired by [N]NH MPI PET/CT and the Effect of Motion Correction Tools.

Mendoza-Ibanez O, Slart R, Alexanderson-Rosas E, Martinez-Lucio T, van der Zant F, Knol R Diagnostics (Basel). 2025; 15(5).

PMID: 40075861 PMC: 11898590. DOI: 10.3390/diagnostics15050613.


TAI-GAN: A Temporally and Anatomically Informed Generative Adversarial Network for early-to-late frame conversion in dynamic cardiac PET inter-frame motion correction.

Guo X, Shi L, Chen X, Liu Q, Zhou B, Xie H Med Image Anal. 2024; 96:103190.

PMID: 38820677 PMC: 11180595. DOI: 10.1016/j.media.2024.103190.


TAI-GAN: Temporally and Anatomically Informed GAN for Early-to-Late Frame Conversion in Dynamic Cardiac PET Motion Correction.

Guo X, Shi L, Chen X, Zhou B, Liu Q, Xie H Simul Synth Med Imaging. 2024; 14288:64-74.

PMID: 38464964 PMC: 10923183. DOI: 10.1007/978-3-031-44689-4_7.


Dynamic cardiac PET motion correction using 3D normalized gradient fields in patients and phantom simulations.

Nye J, Piccinelli M, Hwang D, David Cooke C, Paeng J, Lee J Med Phys. 2021; 48(9):5072-5084.

PMID: 34174095 PMC: 8455441. DOI: 10.1002/mp.15059.


Moving forward with motion reduction, detection and correction in cardiac PET.

Garcia E, Nye J J Nucl Cardiol. 2021; 29(4):1607-1610.

PMID: 33748937 DOI: 10.1007/s12350-021-02599-6.


References
2.
El Fakhri G, Sitek A, Guerin B, Kijewski M, Di Carli M, Moore S . Quantitative dynamic cardiac 82Rb PET using generalized factor and compartment analyses. J Nucl Med. 2005; 46(8):1264-71. View

3.
Kaufmann P, Camici P . Myocardial blood flow measurement by PET: technical aspects and clinical applications. J Nucl Med. 2005; 46(1):75-88. View

4.
Lu Y, Sweiss N . Role of F-FDG PET/CT in Cardiac Sarcoid Detection and Therapy Monitoring: Addition to the Expert Consensus. J Nucl Med. 2018; . DOI: 10.2967/jnumed.118.221549. View

5.
Reilhac A, Merida I, Irace Z, Stephenson M, Weekes A, Chen C . Development of a Dedicated Rebinner with Rigid Motion Correction for the mMR PET/MR Scanner, and Validation in a Large Cohort of C-PIB Scans. J Nucl Med. 2018; 59(11):1761-1767. DOI: 10.2967/jnumed.117.206375. View

6.
Lee B, Moody J, Poitrasson-Riviere A, Melvin A, Weinberg R, Corbett J . Automated dynamic motion correction using normalized gradient fields for rubidium PET myocardial blood flow quantification. J Nucl Cardiol. 2018; 27(6):1982-1998. PMC: 6504625. DOI: 10.1007/s12350-018-01471-4. View