» Articles » PMID: 30419058

Dosimetric and Radiobiological Comparison in Different Dose Calculation Grid Sizes Between Acuros XB and Anisotropic Analytical Algorithm for Prostate VMAT

Overview
Journal PLoS One
Date 2018 Nov 13
PMID 30419058
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

To investigate feasible treatment planning parameters, we aimed to evaluate the dosimetric and radiobiological impact of the dose calculation algorithm and grid size in the volumetric modulated arc therapy (VMAT) plan for prostate cancer. Twenty patients were selected, and the treatment plans were initially generated with anisotropic analytical algorithm (AAA) and recalculated with Acuros XB (AXB) algorithm. Various dose grids were used for AXB (1, 2, and 3 mm) and AAA (1, 3, and 5 mm) plan. Dosimetric parameters such as homogeneity index (HI) and conformity index (CI), and radiobiological parameters such as tumor control probability (TCP) and normal tissue complication probability (NTCP) were calculated. Significant differences were observed in the planning target volume (PTV) coverage between both algorithms, and the V95%, HI, and CI of AAA were significantly affected by grid (p < 0.01). On 1 mm grid, the mean rectal dose difference between both algorithms was 2.87% of the prescription dose (p < 0.01), which was the highest among the critical organs. The TCP and NTCP of the AAA were higher than those of AXB (p < 0.01). Compared to AXB with 1 mm grid, the 2 mm grid showed comparable dose calculation accuracy with short calculation time. This study found that the PTV and rectum show significant differences according to dose calculation algorithm and grid. Considering the dose calculation performance for heterogeneous area, we recommend AXB with 2 mm grid for improving treatment efficiency of prostate VMAT.

Citing Articles

Dosimetric Impact of Prescription Point Placement in Heterogeneous Medium for Conformal Radiotherapy Dose Calculation with Various Algorithms.

Pandu B, Khanna D, Palanisamy M, Jacob S, Manichan S J Med Phys. 2024; 49(3):400-409.

PMID: 39526146 PMC: 11548077. DOI: 10.4103/jmp.jmp_71_24.


Dosimetric comparison and evaluation of two computational algorithms in VMAT treatment plans.

Tsimpoukelli M, Patatoukas G, Chalkia M, Kollaros N, Kougioumtzopoulou A, Michaletou D J Appl Clin Med Phys. 2023; 24(9):e14051.

PMID: 37344987 PMC: 10476991. DOI: 10.1002/acm2.14051.


Radiobiological Comparison of Acuros External Beam and Anisotropic Analytical Algorithm on Esophageal Carcinoma Radiotherapy Treatment Plans.

Wang L, Zhang J, Huang M, Xu B, Li X Dose Response. 2022; 20(3):15593258221105678.

PMID: 35832770 PMC: 9272482. DOI: 10.1177/15593258221105678.


Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT.

Tai D, Oanh L, Phuong P, Sulieman A, Abolaban F, Omer H Saudi J Biol Sci. 2022; 29(8):103336.

PMID: 35754762 PMC: 9213241. DOI: 10.1016/j.sjbs.2022.103336.


Dose Super-Resolution in Prostate Volumetric Modulated Arc Therapy Using Cascaded Deep Learning Networks.

Shin D, Kim K, Kang S, Kang S, Kim J, Kim T Front Oncol. 2020; 10:593381.

PMID: 33304852 PMC: 7701297. DOI: 10.3389/fonc.2020.593381.


References
1.
Srivastava S, Cheng C, Das I . The dosimetric and radiobiological impact of calculation grid size on head and neck IMRT. Pract Radiat Oncol. 2016; 7(3):209-217. DOI: 10.1016/j.prro.2016.10.001. View

2.
Otto K . Volumetric modulated arc therapy: IMRT in a single gantry arc. Med Phys. 2008; 35(1):310-7. DOI: 10.1118/1.2818738. View

3.
Streller T, Rusch U, Herraiz Lablanca M, Minneken I, Najafi Y, Shrestha B . The effect of endorectal balloon on anorectal dose during postoperative volumetric arc radiotherapy of prostate cancer. Radiother Oncol. 2017; 123(3):454-458. DOI: 10.1016/j.radonc.2017.04.014. View

4.
Rong Y, Evans J, Xu-Welliver M, Pickett C, Jia G, Chen Q . Dosimetric evaluation of intensity-modulated radiotherapy, volumetric modulated arc therapy, and helical tomotherapy for hippocampal-avoidance whole brain radiotherapy. PLoS One. 2015; 10(4):e0126222. PMC: 4404135. DOI: 10.1371/journal.pone.0126222. View

5.
Ostheimer C, Hubsch P, Janich M, Gerlach R, Vordermark D . Dosimetric comparison of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in total scalp irradiation: a single institutional experience. Radiat Oncol J. 2016; 34(4):313-321. PMC: 5207369. DOI: 10.3857/roj.2016.01935. View