» Articles » PMID: 30394670

Effect of Screw Access Hole Design on the Fracture Resistance of Implant-supported Zirconia-based Restorations

Overview
Specialty Dentistry
Date 2018 Nov 6
PMID 30394670
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To evaluate the effect of screw access hole design on the fracture resistance of cement-retained implant-supported zirconia-based restorations with screw access holes.

Materials And Methods: Thirty cement-retained implant-supported zirconia-based molar crown specimens were fabricated. The specimens were divided into 3 groups of 10: without access holes (C), with screw access holes (S), and with screw access holes accompanied with a surrounding zirconia wall (W). The veneering ceramic thickness was 0.8 mm in all groups. Implants were vertically mounted in a metal block. Abutments were screwed on the implants and the specimens were cemented to the abutments. A universal testing machine applied compressive forces to the specimens until fracture. Fracture resistance values of the specimens were measured. One-way analysis of variance (ANOVA) and Tukey HSD tests were used to analyze data (P < .05).

Results: The mean fracture resistance values were 5794.85 N for C, 2691.48 N for S, and 3878.06 N for W. The screw access hole design significantly affected the fracture resistance (P < .0001). Significant differences were found between C and S (P < .001), C and W (P < .001), and S and W (P = .026).

Conclusions: The screw access hole decreased the fracture resistance. A surrounding zirconia wall for the screw access hole increased the fracture resistance.

Clinical Significance: Screw access hole design may affect the fracture resistance of cement-retained implant-supported zirconia-based restorations with screw access holes. This study introduced a screw access hole design to improve the fracture resistance of these restorations.

Citing Articles

Risk Factors Associated with Failure and Technical Complications of Implant-Supported Single Crowns: A Retrospective Study.

Larsson A, Manuh J, Chrcanovic B Medicina (Kaunas). 2023; 59(9).

PMID: 37763722 PMC: 10535933. DOI: 10.3390/medicina59091603.


Selection of 1-mm venting or 2.5-mm screw access holes on implant crowns based on cement extrusion and retention capacity.

Zhou H, Ye S, Liu M, Feng H, Wen C BMC Oral Health. 2022; 22(1):108.

PMID: 35366875 PMC: 8976311. DOI: 10.1186/s12903-022-02145-x.


Esthetic Evaluation and Acceptability of Different Hole Designs on Implant Crowns from the Perspective of Patients and Dentists in China.

Wen C, Jiang R, Zhang Z, Lei B, Zhong Y, Zhou H Patient Prefer Adherence. 2022; 16:427-437.

PMID: 35210759 PMC: 8860758. DOI: 10.2147/PPA.S351143.


A Special Design to Facilitate Retrieval of Cement-Retained Zirconia-Based Implant-Supported Restorations.

Farzin M, Derafshi R, Giti R, Taghva M J Dent (Shiraz). 2021; 22(2):132-137.

PMID: 34150950 PMC: 8206602. DOI: 10.30476/DENTJODS.2020.85080.1114.