» Articles » PMID: 30389466

Wrong-Patient Blood Transfusion Error: Leveraging Technology to Overcome Human Error in Intraoperative Blood Component Administration

Overview
Publisher Elsevier
Specialty Health Services
Date 2018 Nov 4
PMID 30389466
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Confirmation of match between patient and blood product remains a manual process in most operating rooms (ORs), and documentation of dual-signature verification remains paper based in most medical institutions. A sentinel event at Johns Hopkins Hospital in which a seriously ill patient undergoing an emergent surgical procedure was transfused with a unit of incompatible red blood cells that had been intended for another patient in an adjacent OR led the hospital to conduct a quality improvement project to improve the safety of intraoperative blood component transfusions.

Methods: A multidisciplinary quality improvement project team led a four-phase implementation of bedside bar code transfusion verification (BBTV) for intraoperative blood product administration. Manual random sample audits of blood component transfusions were used to examine accuracy of documentation from July 2014 through June 2016. After the transition to the Epic anesthesia information management system (AIMS) in July 2016, automated Epic reports were generated to provide population-level audits.

Results: After initiation of BBTV and the addition of Epic AIMS, compliance with obtaining three metrics on documentation of patient identification (two electronic signatures, start and stop times of transfusion, and blood volume transfused) was improved during a one-year period to > 96%. Pre-Epic audits had shown a mean compliance of only 86%, mainly reflecting a lack of paper blood component requisitions.

Conclusion: By implementing BBTV and using a novel intraoperative documentation process within the Epic AIMS, a safer process of blood transfusion in the ORs was initiated and documentation improved.

Citing Articles

Use of Epic Electronic Health Record System for Health Care Research: Scoping Review.

Chishtie J, Sapiro N, Wiebe N, Rabatach L, Lorenzetti D, Leung A J Med Internet Res. 2023; 25:e51003.

PMID: 38100185 PMC: 10757236. DOI: 10.2196/51003.


Implementing a New Electronic Health Record System in a University Hospital: The Effect on Reported Medication Errors.

Linden-Lahti C, Kivivuori S, Lehtonen L, Schepel L Healthcare (Basel). 2022; 10(6).

PMID: 35742071 PMC: 9222436. DOI: 10.3390/healthcare10061020.


Electronic transfusion consent and blood delivering pattern improve the management of blood bank in China.

Jiang L, Zhang G, Hao K, Xiang W, Zhang Q, Xie Y BMC Health Serv Res. 2022; 22(1):561.

PMID: 35473708 PMC: 9044836. DOI: 10.1186/s12913-022-07825-6.


Nurses' hemovigilance knowledge and performance after teach-back, concept map, and lecture: A quasi-experimental study.

Masror Roudsari D, Feizi S, Maghsudlu M Heliyon. 2021; 7(1):e05982.

PMID: 33506134 PMC: 7814151. DOI: 10.1016/j.heliyon.2021.e05982.