Hazardous work zones (i.e., , , and ) are typically established by emergency response teams during hazardous materials (HAZMAT) calls but less consistently for fire responses to segment personnel and response activities in the immediate geographic area around the fire. Despite national guidelines, studies have documented the inconsistent use of respiratory protective equipment by firefighters at the fire scene. In this case-series report, we describe zone gas levels using multigas detectors across five independent fire incident responses all occurring in a large South Florida fire department. Multigas detector data collected at each fire response indicate the presence of sustained levels of volatile organic compounds in the "warm zone" of each fire event. These cases suggest that firefighters should not only implement strategies for multigas detector use within the zone but also include respiratory protection to provide adequate safety from toxic exposures in the zone.

Citing Articles

Associations between Awareness of the Risk of Exposure to Pollutants Occurring at Fire Scenes and Health Beliefs among Metropolitan Firefighters in the Republic of Korea.

Oh H, Kim S, Woo H, Ham S Int J Environ Res Public Health. 2022; 19(14).

PMID: 35886708 PMC: 9318504. DOI: 10.3390/ijerph19148860.


Evaluation of Interventions to Reduce Firefighter Exposures.

Burgess J, Hoppe-Jones C, Griffin S, Zhou J, Gulotta J, Wallentine D J Occup Environ Med. 2020; 62(4):279-288.

PMID: 31977921 PMC: 8647371. DOI: 10.1097/JOM.0000000000001815.

References
1.
Burgess J, Crutchfield C, Storment S, Gerkin R, Wilson J . Characterization of firefighter exposures during fire overhaul. AIHAJ. 2000; 61(5):636-41. DOI: 10.1080/15298660008984572. View

2.
Burgess J, Nanson C, Gerkin R, Hysong T, Lantz R, Sherrill D . Adverse respiratory effects following overhaul in firefighters. J Occup Environ Med. 2001; 43(5):467-73. DOI: 10.1097/00043764-200105000-00007. View

3.
Kahn S, Woods J, Sipes J, Toscano N, Bell D . Firefighter safety: rampant unsafe practices as documented in mainstream media. J Burn Care Res. 2014; 35(5):426-30. DOI: 10.1097/BCR.0000000000000016. View

4.
Brandt-Rauf P, Fallon Jr L, Tarantini T, Idema C, Andrews L . Health hazards of fire fighters: exposure assessment. Br J Ind Med. 1988; 45(9):606-12. PMC: 1009663. DOI: 10.1136/oem.45.9.606. View

5.
Fent K, Eisenberg J, Snawder J, Sammons D, Pleil J, Stiegel M . Systemic exposure to PAHs and benzene in firefighters suppressing controlled structure fires. Ann Occup Hyg. 2014; 58(7):830-45. PMC: 4124999. DOI: 10.1093/annhyg/meu036. View