» Articles » PMID: 30361921

Role of Contrast-enhanced Ultrasound (CEUS) in the Diagnosis and Management of Traumatic Splenic Injuries

Overview
Journal J Ultrasound
Publisher Springer
Specialty Radiology
Date 2018 Oct 27
PMID 30361921
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Splenic injuries are common emergencies in the setting of abdominal trauma, as the spleen is the second most frequently injured abdominal organ after the liver. The treatment of splenic injuries underwent a severe shift from operative to non-operative due to an increased awareness of the double physiological function, both immunological and hematological, of the spleen. This, in turn, led to an increased application of splenic preservation techniques. The non-operative approach has been strengthened through radiological imaging and interventional radiology. While multidetector computed tomography is mandatory in the evaluation of hemodynamically stable patients after high-energy trauma, one ultrasound (US) can be used as a first-line technique to examine patients in cases of low-energy trauma. Unfortunately, baseline US has low sensitivity in the detection of traumatic injuries. With the introduction of contrast-enhanced ultrasound (CEUS) as a reliable alternative to baseline ultrasound for low-grade abdominal trauma, the sensitivity of the US technique in recognizing traumatic abdominal lesions has strongly increased, reaching levels of accuracy similar to those of the CT. It has also been strongly recommended for use with children, as it allows for the performance of imaging techniques with the lowest dose of radiation possible. In this review, the authors aim to present the typical appearance of traumatic splenic injuries, using enhanced CEUS capability to overcome baseline US limits, and to describe the different techniques applied according to the hemodynamic stability of the patient.

Citing Articles

Contrast-enhanced Ultrasound as a Method of Splenic Injury Assessment.

Giordano U, Kobialka J, Bystron J, Dziekiewicz A, Pilch J, Matuszewska K J Med Ultrasound. 2025; 32(4):291-296.

PMID: 39801539 PMC: 11717077. DOI: 10.4103/jmu.jmu_33_24.


Microbubble Contrast Agents Improve Detection of Active Hemorrhage.

Schoen Jr S, Prasov A, Candel I, Arshad S, Ottensmeyer M, Pierce T IEEE Open J Eng Med Biol. 2024; 5:877-884.

PMID: 39559779 PMC: 11573402. DOI: 10.1109/OJEMB.2024.3414974.


Contrast-enhanced ultrasound (CEUS) in the follow-up of abdominal solid organ trauma: an international survey prior to the PseAn study.

Santolamazza G, Virdis F, Abu-Zidan F, Cioffi S, Reitano E, Altomare M Eur J Trauma Emerg Surg. 2023; 50(5):2081-2088.

PMID: 37828351 DOI: 10.1007/s00068-023-02364-z.


Applications of Contrast-Enhanced Ultrasound in Splenic Studies of Dogs and Cats.

Canejo-Teixeira R, Lima A, Santana A Animals (Basel). 2022; 12(16).

PMID: 36009694 PMC: 9404716. DOI: 10.3390/ani12162104.


Splenic Infarction Diagnosed by Contrast-enhanced Ultrasound in Infectious Mononucleosis - An Appropriate Diagnostic Option: A Case Report with Review of the Literature.

Reichlin M, Bosbach S, Minotti B J Med Ultrasound. 2022; 30(2):140-142.

PMID: 35832357 PMC: 9272717. DOI: 10.4103/JMU.JMU_87_21.


References
1.
Peitzman A, Heil B, Rivera L, Federle M, Harbrecht B, Clancy K . Blunt splenic injury in adults: Multi-institutional Study of the Eastern Association for the Surgery of Trauma. J Trauma. 2000; 49(2):177-87; discussion 187-9. DOI: 10.1097/00005373-200008000-00002. View

2.
Valentino M, De Luca C, Galloni S, Branchini M, Modolon C, Pavlica P . Contrast-enhanced US evaluation in patients with blunt abdominal trauma(). J Ultrasound. 2013; 13(1):22-7. PMC: 3552645. DOI: 10.1016/j.jus.2010.06.002. View

3.
Poletti P, Wintermark M, Schnyder P, Becker C . Traumatic injuries: role of imaging in the management of the polytrauma victim (conservative expectation). Eur Radiol. 2002; 12(5):969-78. DOI: 10.1007/s00330-002-1353-y. View

4.
Manetta R, Pistoia M, Bultrini C, Stavroulis E, Di Cesare E, Masciocchi C . Ultrasound enhanced with sulphur-hexafluoride-filled microbubbles agent (SonoVue) in the follow-up of mild liver and spleen trauma. Radiol Med. 2009; 114(5):771-9. DOI: 10.1007/s11547-009-0406-6. View

5.
Poletti P, Kinkel K, Vermeulen B, Irmay F, Unger P, Terrier F . Blunt abdominal trauma: should US be used to detect both free fluid and organ injuries?. Radiology. 2003; 227(1):95-103. DOI: 10.1148/radiol.2271020139. View