Intentional Fracture of Bioprosthetic Valve Frames in Patients Undergoing Valve-in-Valve Transcatheter Pulmonary Valve Replacement
Overview
Authors
Affiliations
Background: Percutaneous transcatheter pulmonary valve replacement (TPVR) has good clinical and hemodynamic outcomes in treating dysfunctional bioprosthetic valves (BPV) in the pulmonary position. Valve-in-valve therapy can further decrease the inner diameter (ID), potentially resulting in patient-prosthesis mismatch in patients with smaller BPVs.
Methods And Results: To evaluate feasibility and outcomes of intentional BPV fracture to enlarge the pulmonary valve orifice with TPVR, 37 patients from 13 centers who underwent TPVR with intended BPV fracture were evaluated. A control cohort (n=70) who underwent valve-in-valve TPVR without attempted fracture was evaluated. BPV was successfully fractured in 28 patients and stretched in 5 while fracture was unsuccessful in 4. A Melody valve was implanted in 25 patients with fractured/stretched frame and a Sapien (XT 3) valve in 8. Among patients whose BPV was fractured/stretched, the final ID was a median of 2 mm larger (0-6.5 mm) than the valve's true ID. The narrowest diameter after TPVR in controls was a median of 2 mm smaller ( P<0.001) than true ID. Right ventricular outflow tract gradient decreased from median 40 to 8 mm Hg in the fracture group. Cases with fracture/stretching were matched 1:1 (weight, true ID) to controls. Post-TPVR peak gradient was lower but not significant (8.3±5.2 versus 11.8±9.2 mm Hg; P=0.070). There were no fracture-related adverse events.
Conclusions: Preliminary experience shows intentional fracture of BPV frame can be useful for achieving larger ID and better hemodynamics after valve-in-valve TPVR.
Belahnech Y, Marti-Aguasca G, Dos-Subira L, Betrian-Blasco P, Garcia Del Blanco B, Calvo-Barcelo M Sci Rep. 2025; 15(1):3977.
PMID: 39893235 PMC: 11787317. DOI: 10.1038/s41598-024-82336-4.
Transcatheter Pulmonary Valve Replacement: A Review of Current Valve Technologies.
Patel N, Levi D, Cheatham J, Qureshi S, Shahanavaz S, Zahn E J Soc Cardiovasc Angiogr Interv. 2024; 1(6):100452.
PMID: 39132347 PMC: 11307711. DOI: 10.1016/j.jscai.2022.100452.
Montana-Jimenez L, Aristizabal A, Mosquera-Alvarez W, Gutierrez-Gil J, Ponce-Bravo L, Beltran E Arch Cardiol Mex. 2024; 94(1):7-14.
PMID: 38507314 PMC: 11160522. DOI: 10.24875/ACM.22000226.
Kagiyama Y, Kenny D, Hijazi Z Glob Cardiol Sci Pract. 2024; 2024(1):e202407.
PMID: 38404661 PMC: 10886730. DOI: 10.21542/gcsp.2024.7.
El-Saiedi S, Attia W, Hanna B, Aboudeif M, Zakaria R, Abd ElMeguid M J Interv Cardiol. 2023; 2023:9709227.
PMID: 36793670 PMC: 9908361. DOI: 10.1155/2023/9709227.