» Articles » PMID: 30348844

Clinical Implications of Real-time and Intermittently Scanned Continuous Glucose Monitoring

Overview
Journal Diabetes Care
Specialty Endocrinology
Date 2018 Oct 24
PMID 30348844
Citations 66
Authors
Affiliations
Soon will be listed here.
Abstract

Two types of continuous glucose monitoring (CGM) systems are now available: real-time CGM (rtCGM) and intermittently scanned (isCGM). Current rtCGM systems automatically transmit a continuous stream of glucose data to the user, provide alerts and active alarms, and transmit glucose data (trend and numerical) in real time to a receiver, smart watch, or smartphone. The current isCGM system provides the same type of glucose data but requires the user to purposely scan the sensor to obtain information, and it does not have alerts and alarms. Both CGM technologies have significant advantages over self-monitoring of blood glucose; however, differences in the features and capabilities of the two approaches must be considered when guiding patient selection of the system that meets their individual needs.

Citing Articles

Evaluation of the Effectiveness of Continuous Glucose Monitors on Glycemic Control in Patients With Type 2 Diabetes Receiving Institutional Financial Assistance.

Cheng K, Vera Cruz M, Tylee T, Kelly M J Diabetes Sci Technol. 2025; :19322968251320122.

PMID: 39980262 PMC: 11843561. DOI: 10.1177/19322968251320122.


Performance of real-time continuous glucose monitoring during track and field training in adolescents with type 1 diabetes.

Zimmer R, Aberer F, Schierbauer J, Zimmermann P, Birnbaumer P, Fritsch M Pediatr Endocrinol Diabetes Metab. 2025; 30(4):211-220.

PMID: 39963058 PMC: 11809549. DOI: 10.5114/pedm.2024.146685.


A Prospective Pilot Study Demonstrating Noninvasive Calibration-Free Glucose Measurement.

Rothenbuhler M, Lizoain A, Rebeaud F, Perotte A, Stoffel M, DeVries J J Diabetes Sci Technol. 2025; :19322968251313811.

PMID: 39881452 PMC: 11780617. DOI: 10.1177/19322968251313811.


The effects of aerobic exercise on 24-hour mean blood glucose levels measured by continuous glucose monitoring in type 2 diabetes: a meta-analysis.

Wang C, Tang S Front Physiol. 2025; 15:1496271.

PMID: 39764380 PMC: 11700982. DOI: 10.3389/fphys.2024.1496271.


Effectiveness of continuous glucose monitoring in patient management of Type 2 Diabetes Mellitus: an umbrella review of systematic reviews from 2011 to 2024.

Tan Y, Suan E, Koh G, Suhairi S, Tyagi S Arch Public Health. 2024; 82(1):231.

PMID: 39623499 PMC: 11610123. DOI: 10.1186/s13690-024-01459-2.