Testing Physiologic Monitor Alarm Customization Software to Reduce Alarm Rates and Improve Nurses' Experience of Alarms in a Medical Intensive Care Unit

Overview
Journal PLoS One
Date 2018 Oct 19
PMID 30335824
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Clinicians in intensive care units experience alarm fatigue related to frequent false and non-actionable alarms produced by physiologic monitors. To reduce non-actionable alarms, alarm settings may need to be customized for individual patients; however, nurses may not customize alarms because of competing demands and alarm fatigue.

Objective: To examine the effectiveness and acceptance of physiologic monitor software to support customization of alarms.

Methods: This pre/post intervention study was conducted in a 56-bed medical intensive care unit. IntelliVue® Alarm Advisor customization support software for alarm limit violations was installed on all monitors and education on its use provided. For 2 months before and after implementation of the software, data were collected on patient characteristics from the electronic health record, alarm counts and duration from the monitoring system, and nurses' experience of alarms from a survey.

Results: Medium-priority heart rate, respiratory rate, and arterial pressure alarms were significantly reduced after software implementation (9.3%, 11.8%, and 15.9% reduction respectively; p<0.001 for all). The duration of these alarms was also significantly shorter (7.8%, 13.3%, and 9.3% reduction respectively; p<0.05 for all). The number and duration of SpO2 alarms did not decrease (p>0.05 for both). Patients post-intervention had worse Glasgow Coma Scale scores (p = 0.014), but otherwise were comparable to those pre-intervention. Nurses reported less time spent on non-actionable alarms post-intervention than pre-intervention (p = 0.026). Also lower post-intervention were the proportions of nurses who reported that alarms disturbed their workflow (p = 0.027) and who encountered a situation where an important alarm was ignored (p = 0.043). The majority (>50%) agreed that the software supported setting appropriate alarm limits and was easy to use.

Conclusion: Alarm customization software was associated with a reduction in alarms. Use of software to support nurses' recognition of trends in patients' alarms and facilitate changes to alarm settings may add value to alarm reduction initiatives.

Citing Articles

Extension of an ICU-based noninvasive model to predict latent shock in the emergency department: an exploratory study.

Wu M, Li S, Yu H, Jiang C, Dai S, Jiang S Front Cardiovasc Med. 2025; 11:1508766.

PMID: 39764280 PMC: 11701063. DOI: 10.3389/fcvm.2024.1508766.


Enhancing Patient Safety Through an Integrated Internet of Things Patient Care System: Large Quasi-Experimental Study on Fall Prevention.

Wen M, Chen P, Lin S, Lien C, Tu S, Chueh C J Med Internet Res. 2024; 26:e58380.

PMID: 39361417 PMC: 11487210. DOI: 10.2196/58380.


Role of artificial intelligence in haemodynamic monitoring.

Myatra S, Jagiasi B, Singh N, Divatia J Indian J Anaesth. 2024; 68(1):93-99.

PMID: 38406336 PMC: 10893816. DOI: 10.4103/ija.ija_1260_23.


The effect of intelligent management interventions in intensive care units to reduce false alarms: An integrative review.

Li B, Yue L, Nie H, Cao Z, Chai X, Peng B Int J Nurs Sci. 2024; 11(1):133-142.

PMID: 38352290 PMC: 10859571. DOI: 10.1016/j.ijnss.2023.12.008.


Pediatric Characteristics Associated With Higher Rates of Monitor Alarms.

Ruppel H, Makeneni S, Rasooly I, Ferro D, Bonafide C Biomed Instrum Technol. 2024; 57(4):171-179.

PMID: 38170941 PMC: 10764059. DOI: 10.2345/0899-8205-57.4.171.


References
1.
De Vaux L, Cooper D, Knudson K, Gasperini M, Rodgerson K, Funk M . Reduction of Nonactionable Alarms in Medical Intensive Care. Biomed Instrum Technol. 2017; 51(s2):58-61. DOI: 10.2345/0899-8205-51.s2.58. View

2.
Whalen D, Covelle P, Piepenbrink J, Villanova K, Cuneo C, Awtry E . Novel approach to cardiac alarm management on telemetry units. J Cardiovasc Nurs. 2013; 29(5):E13-22. DOI: 10.1097/JCN.0000000000000114. View

3.
Welch J . An evidence-based approach to reduce nuisance alarms and alarm fatigue. Biomed Instrum Technol. 2011; Suppl:46-52. DOI: 10.2345/0899-8205-45.s1.46. View

4.
Sendelbach S, Wahl S, Anthony A, Shotts P . Stop the Noise: A Quality Improvement Project to Decrease Electrocardiographic Nuisance Alarms. Crit Care Nurse. 2015; 35(4):15-22. DOI: 10.4037/ccn2015858. View

5.
. Medical device alarm safety in hospitals. Sentinel Event Alert. 2013; (50):1-3. View