» Articles » PMID: 30309270

Sample Management for Clinical Biochemistry Assays: Are Serum and Plasma Interchangeable Specimens?

Overview
Publisher Informa Healthcare
Specialty Pathology
Date 2018 Oct 13
PMID 30309270
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

The constrained economic context leads laboratories to centralize their routine analyses on high-throughput platforms, to which blood collection tubes are sent from peripheral sampling sites that are sometimes distantly located. Providing biochemistry results as quickly as possible implies to consolidate the maximum number of tests on a minimum number of blood collection tubes, mainly serum tubes and/or tubes with anticoagulants. However, depending on the parameters and their pre-analytical conditions, the type of matrix - serum or plasma - may have a significant impact on results, which is often unknown or underestimated in clinical practice. Importantly, the matrix-related effects may be a limit to the consolidation of analyses on a single tube, and thus must be known by laboratory professionals. The purpose of the present critical review is to put forward the main differences between using serum and plasma samples on clinical biochemistry analyses, in order to sensitize laboratory managers to the need for standardization. To enrich the debate, we also provide an additional comparison of serum and plasma concentrations for approximately 30 biochemistry parameters. Properties, advantages, and disadvantages of serum and plasma are discussed from a pre-analytical standpoint - before, during, and after centrifugation - with an emphasis on the importance of temperature, delay, and transport conditions. Then, differences in results between these matrices are addressed for many classes of biochemistry markers, particularly proteins, enzymes, electrolytes, lipids, circulating nucleic acids, metabolomics markers, and therapeutic drugs. Finally, important key-points are proposed to help others choose the best sample matrix and guarantee quality of clinical biochemistry assays. Moreover, awareness of the implications of using serum and plasma samples on various parameters assayed in the laboratory is an important requirement to ensure reliable results and improve patient care.

Citing Articles

Impact of -20 C° cryopreservation on serum factors from schistosomiasis patients at different storage durations: insights into serum bio-banking.

Aladawy A, Elnakib M, Fattah M, Taha A, El Saftawy E J Parasit Dis. 2025; 49(1):162-172.

PMID: 39975625 PMC: 11832841. DOI: 10.1007/s12639-024-01734-7.


Delphinid postmortem vitreous humor biochemistry as proxy for antemortem blood analyte concentrations.

Zorotrian T, Stern A, Costidis A, Harms C, Gao H, Fontaine C Mar Mamm Sci. 2025; 41(1.

PMID: 39850025 PMC: 11753784. DOI: 10.1111/mms.13157.


Effects of Blood Collection Tubes on the Quantification of Catecholamines and Their O-Methylated Metabolites by Liquid Chromatography Coupled With Tandem Mass Spectrometry.

Su R, Wu Y, Huang Q, Huang S, Li Y, Chen C J Clin Lab Anal. 2024; 38(19-20):e25107.

PMID: 39345045 PMC: 11520940. DOI: 10.1002/jcla.25107.


Management of refined and personalized newborn blood specimen collection.

Huang H, Lin Y, Chen J, Zhu M, Chen L, Ye W Pract Lab Med. 2024; 40:e00408.

PMID: 38883564 PMC: 11180333. DOI: 10.1016/j.plabm.2024.e00408.


GC-MS and GC-MS/MS measurement of malondialdehyde (MDA) in clinical studies: Pre-analytical and clinical considerations.

Tsikas D J Mass Spectrom Adv Clin Lab. 2023; 30:10-24.

PMID: 37637438 PMC: 10458701. DOI: 10.1016/j.jmsacl.2023.08.001.