» Articles » PMID: 30300623

Uncured PDMS Inhibits Myosin in Vitro Motility in a Microfluidic Flow Cell

Overview
Journal Anal Biochem
Publisher Elsevier
Specialty Biochemistry
Date 2018 Oct 10
PMID 30300623
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

The myosin motor powers cardiac contraction and is frequently implicated in hereditary heart disease by its mutation. Principal motor function characteristics include myosin unitary step size, duty cycle, and force-velocity relationship for translating actin under load. These characteristics are sometimes measured in vitro with a motility assay detecting fluorescent labeled actin filament gliding velocity over a planar array of surface immobilized myosin. Assay miniaturization in a polydimethylsiloxane/glass (PDMS/glass) hybrid microfluidic flow channel is an essential component to a small sample volume assay applicable to costly protein samples however the PDMS substrate dramatically inhibits myosin motility. Myosin in vitro motility in a PDMS/glass hybrid microfluidic flow cell was tested under a variety of conditions to identify and mitigate the effect of PDMS on myosin. Substantial contamination by unpolymerized species in the PDMS flow cells is shown to be the cause of myosin motility inhibition. Normal myosin motility recovers by either extended cell aging (~20 days) to allow more complete polymerization or by direct chemical extraction of the unpolymerized species from the polymer substrate. PDMS flow cell aging is the low cost alternative compatible with the other PDMS and glass modifications needed for in vitro myosin motility assaying.

Citing Articles

Organ-on-chip applications in drug discovery: an end user perspective.

Clapp N, Amour A, Rowan W, Candarlioglu P Biochem Soc Trans. 2021; 49(4):1881-1890.

PMID: 34397080 PMC: 8421049. DOI: 10.1042/BST20210840.

References
1.
Kron S, Toyoshima Y, Uyeda T, Spudich J . Assays for actin sliding movement over myosin-coated surfaces. Methods Enzymol. 1991; 196:399-416. DOI: 10.1016/0076-6879(91)96035-p. View

2.
Vickers J, Caulum M, Henry C . Generation of hydrophilic poly(dimethylsiloxane) for high-performance microchip electrophoresis. Anal Chem. 2006; 78(21):7446-52. DOI: 10.1021/ac0609632. View

3.
Ng J, Gitlin I, Stroock A, Whitesides G . Components for integrated poly(dimethylsiloxane) microfluidic systems. Electrophoresis. 2002; 23(20):3461-73. DOI: 10.1002/1522-2683(200210)23:20<3461::AID-ELPS3461>3.0.CO;2-8. View

4.
Aksel T, Yu E, Sutton S, Ruppel K, Spudich J . Ensemble force changes that result from human cardiac myosin mutations and a small-molecule effector. Cell Rep. 2015; 11(6):910-920. PMC: 4431957. DOI: 10.1016/j.celrep.2015.04.006. View

5.
Makamba H, Kim J, Lim K, Park N, Hahn J . Surface modification of poly(dimethylsiloxane) microchannels. Electrophoresis. 2003; 24(21):3607-19. DOI: 10.1002/elps.200305627. View