» Articles » PMID: 30291435

New IPAD-based Test for the Detection of Color Vision Deficiencies

Overview
Specialty Ophthalmology
Date 2018 Oct 7
PMID 30291435
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To develop and validate a new iPad-based color vision test (Optopad).

Methods: A total of 341 student eyes were enrolled in a first comparative study between Optopad and the Isihara tests. In a second comparative study, Optopad vs. the Farnworth-Munsell test (FM 100H), a total of 66 adult eyes were included. Besides the agreement between tests, the correlation between FM 100H and Optopad outcomes were investigated. Multiple regression analysis was used to predict the total error score (TES) from contrast thresholds measured with the Optopad test.

Results: The Ishihara and Optopad tests detected the same anomalous patients. Concerning FM 100H vs. Optopad, 10 subjects were diagnosed as anomalous with both tests, 3 mild anomalous cases based on TES were classified as normal with Optopad, and 2 anomalous subjects based on Optopad test showed normal TES values. Statistically significant correlations of TES and partial error red-green (PTESRG) with thresholds measured with the red-green Optopad stimuli were found. A multiple quadratic regression model was obtained relating TES and chromatic contrast values from Optopad (R = 0.855), with only 13 cases showing residuals of ≥ 25 units.

Conclusions: The design and implementation of a chromatic contrast discrimination test has been carried out, with promising clinical results. This test seems to provide comparable outcomes to those obtained with Ishihara and FM 100H tests.

Citing Articles

Validation of a New Test for Measuring the Contrast Sensitivity Function (Optopad-CSF) at Near Vision.

de Fez D, Garcia C, Luque-Cobija M, Mena-Guevara K, Dauden P, Pinero D Diagnostics (Basel). 2024; 14(13).

PMID: 39001266 PMC: 11241259. DOI: 10.3390/diagnostics14131377.


Validation of a New Digital and Automated Color Perception Test.

Fanlo-Zarazaga A, Echevarria J, Pinilla J, Alejandre A, Perez-Roche T, Gutierrez D Diagnostics (Basel). 2024; 14(4).

PMID: 38396435 PMC: 10888327. DOI: 10.3390/diagnostics14040396.


Correlation between color vision, visual acuity, contrast sensitivity and photostress recovery in the visually impaired: a cross-sectional study.

Almaliotis D, Almpanidou S, Chatzimbalis T, Nikolaidou A, Talimtzi P, Karampatakis V Ann Med Surg (Lond). 2024; 86(2):742-747.

PMID: 38333302 PMC: 10849460. DOI: 10.1097/MS9.0000000000001522.


Visual perception alterations in COVID-19: a preliminary study.

Coco-Martin M, Leal-Vega L, Alcoceba-Herrero I, Molina-Martin A, de-Fez D, Luque M Int J Ophthalmol. 2023; 16(1):1-9.

PMID: 36659948 PMC: 9815973. DOI: 10.18240/ijo.2023.01.01.


Validation of Digital Applications for Evaluation of Visual Parameters: A Narrative Review.

Mena-Guevara K, Pinero D, de Fez D Vision (Basel). 2021; 5(4).

PMID: 34842847 PMC: 8628957. DOI: 10.3390/vision5040058.


References
1.
Barton F, Fong D, Knatterud G . Classification of Farnsworth-Munsell 100-hue test results in the early treatment diabetic retinopathy study. Am J Ophthalmol. 2004; 138(1):119-24. DOI: 10.1016/j.ajo.2004.02.009. View

2.
Rabin J, Gooch J, Ivan D . Rapid quantification of color vision: the cone contrast test. Invest Ophthalmol Vis Sci. 2010; 52(2):816-20. DOI: 10.1167/iovs.10-6283. View

3.
de Fez D, Luque M, Garcia-Domene M, Camps V, Pinero D . Colorimetric Characterization of Mobile Devices for Vision Applications. Optom Vis Sci. 2015; 93(1):85-93. DOI: 10.1097/OPX.0000000000000752. View

4.
Black J, Jacobs R, Phillips G, Chen L, Tan E, Tran A . An assessment of the iPad as a testing platform for distance visual acuity in adults. BMJ Open. 2013; 3(6). PMC: 3693417. DOI: 10.1136/bmjopen-2013-002730. View

5.
Birch J . Use of the Farnsworth-Munsell 100-Hue test in the examination of congenital colour vision defects. Ophthalmic Physiol Opt. 1989; 9(2):156-62. DOI: 10.1111/j.1475-1313.1989.tb00836.x. View