» Articles » PMID: 30251193

Real-time Surveillance of Left Atrial Appendage Thrombus During Contrast Computed Tomography Imaging for Catheter Ablation: THe Reliability of COMputed Tomography Beyond UltraSound in THROMBUS Detection (THROMBUS) Study

Abstract

Left atrial contrast computed tomography (LA-CT) as well as transesophageal echocardiography (TEE) can exclude left atrial appendage (LAA) thrombus, but is sometimes unable to evaluate LAA due to incomplete LAA filling. The aim of the current study was to validate the utility of real-time approach of LA-CT with real-time surveillance of LAA-filling defect (FD). We enrolled consecutive 894 patients with LA-CT studies acquired for catheter ablation and compared the diagnostic accuracy in demonstrating LAA-FD between conventional protocol (N = 474) and novel protocol with real-time surveillance of LAA-FD immediately after the initial scanning and, when necessary, adding delayed scanning in the supine or prone position (N = 420). Primary endpoint was severity of LAA-FD classified into the 3 groups: "Grade-0" for complete filling of contrast, "Grade-1" for incomplete filling of contrast, and "Grade-2" for complete FD of contrast. The prevalence of Grade-1 and Grade-2 FD was 17.3% and 11.2% in conventional protocol, whereas there was no patient with Grade-2 FD, and only 1 patient with Grade-1 FD after the additional scanning in novel protocol. In 5 patients with suspected LAA thrombus both by TEE and Grade-2 FD in LA-CT by the conventional protocol, ablation procedure was canceled due to diagnosis of LAA thrombus. Conversely, 4 patients with suspected LAA thrombus by TEE in novel protocol group was proved to have intact LAA by LA-CT with and without additional scanning. This novel approach with real-time surveillance improved the diagnostic accuracy of LA-CT in detecting LAA-FD, suggesting potential superiority of LA-CT over TEE in excluding LAA thrombus.

Citing Articles

Different scanning protocol to assess left atrial appendage thrombus in patients with atrial fibrillation by cardiovascular computed tomography.

Sun C, Lv J, Liu M, Ma H Sci Rep. 2024; 14(1):30414.

PMID: 39639098 PMC: 11621552. DOI: 10.1038/s41598-024-81708-0.


Preoperative diagnostic value of multimodal spectral CT for patients with atrial fibrillation undergoing radiofrequency ablation.

Yu N, Hong Y, Lv X, Liu Q, Yan M Front Med (Lausanne). 2024; 11:1440020.

PMID: 39328316 PMC: 11425045. DOI: 10.3389/fmed.2024.1440020.


Left atrial appendage filling defect in exclusive early-phase scanning of dual-phase cardiac computed tomography: An indicator for elevated thromboembolic risk.

Qiao Y, Zhao Z, Cai X, Guo Y, Liu K, Guo J Cardiol J. 2023; 31(1):95-102.

PMID: 36896637 PMC: 10919564. DOI: 10.5603/CJ.a2023.0014.


Cardiac Computed Tomography Versus Transesophageal Echocardiography for the Detection of Left Atrial Appendage Thrombus: A Systemic Review and Meta-Analysis.

Yu S, Zhang H, Li H J Am Heart Assoc. 2021; 10(23):e022505.

PMID: 34796743 PMC: 9075398. DOI: 10.1161/JAHA.121.022505.


Prone-position computed tomography in the late phase for detecting intracardiac thrombi in the left atrial appendage before catheter ablation for atrial fibrillation.

Nakamura R, Oda A, Tachibana S, Sudo K, Shigeta T, Sagawa Y J Cardiovasc Electrophysiol. 2021; 32(7):1803-1811.

PMID: 33969567 PMC: 8359968. DOI: 10.1111/jce.15062.


References
1.
Tani T, Yamakami S, Matsushita T, Okamoto M, Toyama J, Suzuki S . Usefulness of electron beam tomography in the prone position for detecting atrial thrombi in chronic atrial fibrillation. J Comput Assist Tomogr. 2003; 27(1):78-84. DOI: 10.1097/00004728-200301000-00014. View

2.
Donal E, Yamada H, Leclercq C, Herpin D . The left atrial appendage, a small, blind-ended structure: a review of its echocardiographic evaluation and its clinical role. Chest. 2005; 128(3):1853-62. DOI: 10.1378/chest.128.3.1853. View

3.
Kim Y, Klein A, Halliburton S, Popovic Z, Kuzmiak S, Sola S . Left atrial appendage filling defects identified by multidetector computed tomography in patients undergoing radiofrequency pulmonary vein antral isolation: a comparison with transesophageal echocardiography. Am Heart J. 2007; 154(6):1199-205. DOI: 10.1016/j.ahj.2007.08.004. View

4.
Martinez M, Kirsch J, Williamson E, Syed I, Feng D, Ommen S . Utility of nongated multidetector computed tomography for detection of left atrial thrombus in patients undergoing catheter ablation of atrial fibrillation. JACC Cardiovasc Imaging. 2009; 2(1):69-76. DOI: 10.1016/j.jcmg.2008.09.011. View

5.
Bertaglia E, Della Bella P, Tondo C, Proclemer A, Bottoni N, De Ponti R . Image integration increases efficacy of paroxysmal atrial fibrillation catheter ablation: results from the CartoMerge Italian Registry. Europace. 2009; 11(8):1004-10. DOI: 10.1093/europace/eup152. View