The Utilization of Metal Augments Allows Better Biomechanical Reconstruction of the Hip in Revision Total Hip Arthroplasty With Severe Acetabular Defects: A Comparative Study

Overview
Journal J Arthroplasty
Specialty Orthopedics
Date 2018 Sep 24
PMID 30243881
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Reconstructing the normal hip biomechanics is important for a successful revision total hip arthroplasty (THA). Little is known about whether using metal augments in revision THA is biomechanically superior to traditional techniques.

Methods: A retrospective review was conducted on 74 consecutive THAs revised using metal augments with a cementless hemispherical cup and 77 consecutive THAs revised using the jumbo cup, all with a minimum 2-year follow-up. Biomechanical parameters were measured before and immediately after the revision. Radiological and clinical outcomes at follow-ups were also evaluated.

Results: The metal augment group had a reconstructed center of rotation (COR) that was 6.5 mm closer to the anatomic COR in height (P < .001), had 3.6 m smaller cup size (P < .001), and had 5.7 mm less head-cup difference (P < .001). Moreover, there was a reconstructed COR that was much closer to the anatomic COR (vertical distance: 1.8 vs 14.1 mm, P < .001; horizontal distance: -2.1 vs 7.9 mm, P = .013), had 4.1 mm greater femoral offset (P = .006), and had 8 mm less leg length discrepancy (P = .035) in the subgroup of Paprosky type III bone defects when compared to the jumbo cup group. All cup-augment constructs were radiologically stable with a higher mean postoperative Harris Hip Score (P = .012). One jumbo cup was radiologically unstable.

Conclusion: In revision THA, utilizing metal augments helps to restore the COR position more precisely, avoid using a larger cup, reduce head-cup difference, rebuild femoral offset, and decrease leg length discrepancy, particularly with Paprosky type III bone defects. Moreover, it provides satisfactory radiological and clinical outcomes in the short term.

Citing Articles

Revision total hip arthroplasty with medial wall defect using bone graft with or without porous metal restrictor.

Do M, Kang S, Lee S, Kim J, Suh K, Shin W Sci Rep. 2024; 14(1):27321.

PMID: 39521825 PMC: 11550414. DOI: 10.1038/s41598-024-78390-7.


[Advances in revision surgery after primary total hip arthroplasty for Crowe type developmental dysplasia of the hip].

Liu Y, Li S, Cheng Q, Mu J Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2023; 37(12):1548-1555.

PMID: 38130200 PMC: 10739673. DOI: 10.7507/1002-1892.202309016.


Medial wall reconstruction using metal disc augments in revision total hip arthroplasty.

Deng W, Wu T, Wang Z, Shao H, Yang D, Zhou Y Int Orthop. 2023; 47(5):1203-1212.

PMID: 36810967 DOI: 10.1007/s00264-023-05723-y.


Extended Fixation for Paprosky Type III Acetabular Defects in Revision Total Hip Arthroplasty with a Minimum Follow-Up of 2 Years.

Tang H, Huang Y, Zhou Y, Ma Z, Guo S Orthop Surg. 2022; 15(1):205-213.

PMID: 36419313 PMC: 9837286. DOI: 10.1111/os.13577.


Clinical and radiological outcomes of jumbo cup in revision total hip arthroplasty: A systematic review.

Wang Q, Wang Q, Liu P, Ge J, Zhang Q, Guo W Front Surg. 2022; 9:929103.

PMID: 36268211 PMC: 9577022. DOI: 10.3389/fsurg.2022.929103.