» Articles » PMID: 30218354

Individualized Alignment in Total Knee Arthroplasty Using Image-based Robotic Assistance : Video Article

Overview
Journal Orthopade
Specialty Orthopedics
Date 2018 Sep 16
PMID 30218354
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Over the past decades many innovations were introduced in total knee arthroplasty (TKA) focusing on implant longevity and higher procedural precision; however, there are still a high number of dissatisfied patients. It was reported that better anatomical alignment may result in improved patient outcome; however, current technologies have limitations to achieve this. The aim of this video article is to describe the technique of individualized alignment in TKA with the use of image-based robotic assistance.

Methods: The technology is based on an individual patient knee model computed from segmented computed tomography (CT) scans. A preoperative planning of prosthesis position is conducted following the principle of kinematic alignment. Intraoperatively the soft tissue envelope is recorded and the computer predicts the gap balance based on the virtual planning. The prosthesis position is then adapted to achieve balanced gaps and to avoid soft tissue release. This technique is shown in a cadaver operation and clinical examples of two patients are described.

Results: With the combination of anatomically oriented prosthesis positioning and minor adaptations with respect to the soft tissue, an individualized alignment is achieved with reduced need of soft tissue release. The robotic-assisted surgery guarantees a precise implementation of the planning. The initial experience showed a promising outcome in short-term follow-up.

Citing Articles

A case-matched series comparing functional outcomes for robotic-assisted unicompartmental knee arthroplasty versus functionally aligned robotic-assisted total knee arthroplasty.

Manara J, Nixon M, Tippett B, Pretty W, Collopy D, Clark G Bone Jt Open. 2024; 5(12):1123-1129.

PMID: 39701140 PMC: 11658844. DOI: 10.1302/2633-1462.512.BJO-2024-0086.R2.


Same same but different-Image-based versus imageless robotic-assisted total knee arthroplasty!.

Hirschmann M, Avram G, Graichen H, Tandogan R, Mengis N, Zaffagnini S J Exp Orthop. 2024; 11(4):e70062.

PMID: 39429890 PMC: 11489859. DOI: 10.1002/jeo2.70062.


Variability in Alignment and Bone Resections in Robotically Balanced Total Knee Arthroplasties.

Hepinstall M, Di Gangi C, Oakley C, Sybert M, Meere P, Meftah M Bioengineering (Basel). 2024; 11(8).

PMID: 39199803 PMC: 11351558. DOI: 10.3390/bioengineering11080845.


Methods of alignment in total knee arthroplasty, systematic review.

Segura-Nuez Sr J, Martin-Hernandez Sr C, Segura-Nuez Sr J, Segura-Mata Sr J Orthop Rev (Pavia). 2024; 16:117769.

PMID: 38827414 PMC: 11142931. DOI: 10.52965/001c.117769.


Valgus alignment of the femoral component is associated with higher revision rates 10 years after TKA.

Luyckx T, Moreels R, Geernaert H, Scheys L, Vandenneucker H Knee Surg Sports Traumatol Arthrosc. 2023; 31(10):4171-4178.

PMID: 37154911 DOI: 10.1007/s00167-023-07448-2.


References
1.
Burnett R, Barrack R . Computer-assisted total knee arthroplasty is currently of no proven clinical benefit: a systematic review. Clin Orthop Relat Res. 2012; 471(1):264-76. PMC: 3528921. DOI: 10.1007/s11999-012-2528-8. View

2.
Nakamura S, Tian Y, Tanaka Y, Kuriyama S, Ito H, Furu M . The effects of kinematically aligned total knee arthroplasty on stress at the medial tibia: A case study for varus knee. Bone Joint Res. 2017; 6(1):43-51. PMC: 5301901. DOI: 10.1302/2046-3758.61.BJR-2016-0090.R1. View

3.
Calliess T, Ettinger M, Stukenborg-Colsmann C, Windhagen H . [Kinematic alignment in total knee arthroplasty : Concept, evidence base and limitations]. Orthopade. 2015; 44(4):282-6, 288. DOI: 10.1007/s00132-015-3077-0. View

4.
Smith C, Vignos M, Lenhart R, Kaiser J, Thelen D . The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement. J Biomech Eng. 2016; 138(2):021017. PMC: 4844247. DOI: 10.1115/1.4032464. View

5.
Calliess T, Bauer K, Stukenborg-Colsman C, Windhagen H, Budde S, Ettinger M . PSI kinematic versus non-PSI mechanical alignment in total knee arthroplasty: a prospective, randomized study. Knee Surg Sports Traumatol Arthrosc. 2016; 25(6):1743-1748. DOI: 10.1007/s00167-016-4136-8. View