Between-session Reliability of Opto-electronic Motion Capture in Measuring Sagittal Posture and 3-D Ranges of Motion of the Thoracolumbar Spine

Overview
Journal J Biomech
Specialty Physiology
Date 2018 Sep 15
PMID 30213648
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

This study evaluated between-session reliability of opto-electronic motion capture to measure trunk posture and three-dimensional ranges of motion (ROM). Nineteen healthy participants aged 24-74 years underwent spine curvature, pelvic tilt and trunk ROM measurements on two separate occasions. Rigid four-marker clusters were attached to the skin overlying seven spinous processes, plus single markers on pelvis landmarks. Rigid body rotations of spine marker clusters were calculated to determine neutral posture and ROM in flexion, extension, total lateral bending (left-right) and total axial rotation (left-right). Segmental spine ROM values were in line with previous reports using opto-electronic motion capture. Intraclass correlation coefficients (ICC) and standard error of measurement (SEM) were calculated as measures of between-session reliability and measurement error, respectively. Retroreflective markers showed fair to excellent between-session reliability to measure thoracic kyphosis, lumbar lordosis, and pelvic tilt (ICC = 0.82, 0.63, and 0.54, respectively). Thoracic and lumbar segments showed highest reliabilities in total axial rotation (ICC = 0.78) and flexion-extension (ICC = 0.77-0.79) ROM, respectively. Pelvic segment showed highest ICC values in flexion (ICC = 0.78) and total axial rotation (ICC = 0.81) trials. Furthermore, it was estimated that four or fewer repeated trials would provide good reliability for key ROM outcomes, including lumbar flexion, thoracic and lumbar lateral bending, and thoracic axial rotation. This demonstration of reliability is a necessary precursor to quantifying spine kinematics in clinical studies, including assessing changes due to clinical treatment or disease progression.

Citing Articles

Validity and Reliability of Kinovea for Pelvic Kinematic Measurement in Standing Position and in Sitting Position with 45° of Hip Flexion.

Vicente-Pina L, Sanchez-Rodriguez R, Ferrandez-Laliena L, Heredia-Jimenez J, Muller-Thyssen-Uriarte J, Monti-Ballano S Sensors (Basel). 2025; 25(1.

PMID: 39797041 PMC: 11723398. DOI: 10.3390/s25010250.


Optical Marker-Based Motion Capture of the Human Spine: A Scoping Review of Study Design and Outcomes.

Romero-Flores C, Bustamante-Bello R, Moya Bencomo M, Martinez-Rios E, Montesinos L Ann Biomed Eng. 2024; 52(9):2373-2387.

PMID: 39023832 PMC: 11329589. DOI: 10.1007/s10439-024-03567-0.


Measurement properties of 72 movement biomarkers aiming to discriminate non‑specific chronic low back pain patients from an asymptomatic population.

Moissenet F, Armand S, Genevay S Sci Rep. 2023; 13(1):6483.

PMID: 37081110 PMC: 10119171. DOI: 10.1038/s41598-023-33504-5.


Rehabilitation Practitioners' Perceptions of Optimal Sitting and Standing Posture in Men with Normal Weight and Obesity.

Ye J, Jiang Z, Chen S, Cheng R, Xu L, Tsai T Bioengineering (Basel). 2023; 10(2).

PMID: 36829704 PMC: 9952014. DOI: 10.3390/bioengineering10020210.


Analysis of the Active Measurement Systems of the Thoracic Range of Movements of the Spine: A Systematic Review and a Meta-Analysis.

Esteban-Gonzalez P, Sanchez-Romero E, Villafane J Sensors (Basel). 2022; 22(8).

PMID: 35459026 PMC: 9026805. DOI: 10.3390/s22083042.


References
1.
Dunk N, Lalonde J, Callaghan J . Implications for the use of postural analysis as a clinical diagnostic tool: reliability of quantifying upright standing spinal postures from photographic images. J Manipulative Physiol Ther. 2005; 28(6):386-92. DOI: 10.1016/j.jmpt.2005.06.006. View

2.
Martin B, Deyo R, Mirza S, Turner J, Comstock B, Hollingworth W . Expenditures and health status among adults with back and neck problems. JAMA. 2008; 299(6):656-64. DOI: 10.1001/jama.299.6.656. View

3.
Zemp R, List R, Gulay T, Elsig J, Naxera J, Taylor W . Soft tissue artefacts of the human back: comparison of the sagittal curvature of the spine measured using skin markers and an open upright MRI. PLoS One. 2014; 9(4):e95426. PMC: 3991691. DOI: 10.1371/journal.pone.0095426. View

4.
Schmid S, Studer D, Hasler C, Romkes J, Taylor W, Brunner R . Using Skin Markers for Spinal Curvature Quantification in Main Thoracic Adolescent Idiopathic Scoliosis: An Explorative Radiographic Study. PLoS One. 2015; 10(8):e0135689. PMC: 4535911. DOI: 10.1371/journal.pone.0135689. View

5.
Rast F, Graf E, Meichtry A, Kool J, Michael Bauer C . Between-day reliability of three-dimensional motion analysis of the trunk: A comparison of marker based protocols. J Biomech. 2016; 49(5):807-811. DOI: 10.1016/j.jbiomech.2016.02.030. View