» Articles » PMID: 30211746

Innovative Development of Contact Lenses

Overview
Journal Cornea
Specialty Ophthalmology
Date 2018 Sep 14
PMID 30211746
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Contact lenses have been a common means of vision correction for more than half a century. Recent developments have raised the possibility that the next few decades will see a considerable broadening of the range of applications for contact lenses, with associated expansions in the number and type of individuals who consider them a valuable option. The novel applications of contact lenses include treatment platforms for myopic progression, biosensors, and ocular drug delivery. Orthokeratology has shown the most consistent treatment for myopia control with the least side effects. Recent work has resulted in commercialization of a device to monitor intraocular pressure for up to 24 hours, and extensive efforts are underway to develop a contact lens sensor capable of continuous glucose tear film monitoring for the management of diabetes. Other studies on drug-eluting contact lenses have focused on increasing the release duration through molecular imprinting, use of vitamin E, and increased drug binding to polymers by sandwiching a poly (lactic-co-glycolic acid) layer in the lens. This review demonstrates the potential for contact lenses to provide novel opportunities for refractive management, diagnosis, and management of diseases.

Citing Articles

A Hydrogel Ionic Circuit Based High-Intensity Iontophoresis Device for Intraocular Macromolecule and Nanoparticle Delivery.

Zhao F, Fan S, Ghate D, Romanova S, Bronich T, Zhao S Adv Mater. 2021; 34(5):e2107315.

PMID: 34716729 PMC: 8813891. DOI: 10.1002/adma.202107315.

References
1.
Kim J, Chauhan A . Dexamethasone transport and ocular delivery from poly(hydroxyethyl methacrylate) gels. Int J Pharm. 2008; 353(1-2):205-22. DOI: 10.1016/j.ijpharm.2007.11.049. View

2.
Twa M, Roberts C, Karol H, Mahmoud A, Weber P, Small R . Evaluation of a contact lens-embedded sensor for intraocular pressure measurement. J Glaucoma. 2010; 19(6):382-90. PMC: 3073136. DOI: 10.1097/IJG.0b013e3181c4ac3d. View

3.
Schrader S, Wedel T, Moll R, Geerling G . Combination of serum eye drops with hydrogel bandage contact lenses in the treatment of persistent epithelial defects. Graefes Arch Clin Exp Ophthalmol. 2006; 244(10):1345-9. DOI: 10.1007/s00417-006-0257-y. View

4.
Mansouri K, Shaarawy T . Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: initial clinical experience in patients with open angle glaucoma. Br J Ophthalmol. 2011; 95(5):627-9. DOI: 10.1136/bjo.2010.192922. View

5.
Cunliffe D, Kirby A, Alexander C . Molecularly imprinted drug delivery systems. Adv Drug Deliv Rev. 2005; 57(12):1836-53. DOI: 10.1016/j.addr.2005.07.015. View