Comparison of Two Apnea Test Methods, Oxygen Insufflation and Continuous Positive Airway Pressure During Diagnosis of Brain Death: Final Report

Overview
Journal Neurocrit Care
Specialty Critical Care
Date 2018 Sep 14
PMID 30209714
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Deterioration of the pulmonary function after the apnea test (AT) conducted with the classic oxygen insufflation AT (I-AT) is often observed during the brain death (BD) diagnosis procedure. In the present study, two AT methods were compared before a method is recommended for the currently revised Polish BD criteria.

Methods: Classic I-AT and continuous positive airway pressure AT (CPAP-AT) were performed in 60 intensive care unit patients. I-AT was performed at the end of two series of clinical tests, and approximately 1-1.5 h later, after BD was confirmed, a different method, CPAP-AT with 100% FiO and CPAP value of 10 cm HO provided by a ventilator in CPAP mode was performed. The patients in I-AT and CPAP-AT groups were further divided into two subgroups: non-hypoxemic (NH) with good lung function before AT (PaO/FiO index ≥ 200 mmHg) and hypoxemic (H) with poor lung function (PaO/FiO index < 200 mmHg). PaO and PaCO were recorded prior to I-AT and CPAP-AT at time-point one (T1), 5 min after each test at time-point two (T2), and after 10 min prior to the end of tests at time-point three (T3). The I-AT NH subgroup consisted of 50 patients, and CPAP-AT NH subgroup 43 patients. The I-AT H subgroup consisted of 10 patients, and the CPAP-AT H subgroup 17 patients.

Results: In the I-AT NH subgroup, a gradual decrease in PaO/FiO was observed throughout the AT but not in the CPAP-AT NH subgroup. The PaO/FiO ratio during the AT in the CPAP-AT H group was stable with a slight tendency to increase but not in the I-AT H group. During the first 5 min of the AT, the mean increase in CO was approximately 5 mmHg/min. Most patients in all groups met the AT criteria after 5 min of the test.

Conclusions: The results from the study show that I-AT may compromise pulmonary function in some cases and is one of the reasons for the recommendation of a safer option, CPAP-AT, in the currently revised Polish BD criteria. During AT, the mean CO increase rate was 5 mmHg/min, which, in most patients, would allow the test to be completed after just 5 min.

Citing Articles

Detection of spontaneous breathing during an apnea test in a patient with suspected brain death using electrical impedance tomography: a case report.

Chen R, Lovas A, Bakos P, Molnar T, Hawchar F, Benyo B BMC Pulm Med. 2024; 24(1):454.

PMID: 39285376 PMC: 11406830. DOI: 10.1186/s12890-024-03283-4.


Apnea Testing on Conventional Mechanical Ventilation During Brain Death Evaluation.

Merchant R, Ahmad S, Haddix B, Williamson C, Jacobs T, Singh T Neurocrit Care. 2024; 41(2):426-433.

PMID: 38664328 PMC: 11377646. DOI: 10.1007/s12028-024-01990-8.


Pediatric and Adult Brain Death/Death by Neurologic Criteria Consensus Guideline.

Greer D, Kirschen M, Lewis A, Gronseth G, Rae-Grant A, Ashwal S Neurology. 2023; 101(24):1112-1132.

PMID: 37821233 PMC: 10791061. DOI: 10.1212/WNL.0000000000207740.


Invitation to participate in a multi-center study for validation of cerebral computed tomography angiography and computed tomography perfusion in the determination of cerebral circulatory arrest during brain death/death by neurological criteria....

Bohatyrewicz R, Solek-Pastuszka J, Walas W, Sznajder K, Falba A, Chamier-Cieminska K Anaesthesiol Intensive Ther. 2021; 53(2):97-102.

PMID: 34284550 PMC: 10158428. DOI: 10.5114/ait.2021.107189.


Apnea Testing for the Determination of Brain Death: A Systematic Scoping Review.

Busl K, Lewis A, Varelas P Neurocrit Care. 2020; 34(2):608-620.

PMID: 32524528 PMC: 7286635. DOI: 10.1007/s12028-020-01015-0.

References
1.
Citerio G, Crippa I, Bronco A, Vargiolu A, Smith M . Variability in brain death determination in europe: looking for a solution. Neurocrit Care. 2014; 21(3):376-82. DOI: 10.1007/s12028-014-9983-x. View

2.
Wijdicks E, Varelas P, Gronseth G, Greer D . Evidence-based guideline update: determining brain death in adults: report of the Quality Standards Subcommittee of the American Academy of Neurology. Neurology. 2010; 74(23):1911-8. DOI: 10.1212/WNL.0b013e3181e242a8. View

3.
Pabisiak K . Brain death criteria formulated for transplantation purposes: fact or myth?. Anaesthesiol Intensive Ther. 2016; 48(2):142-5. DOI: 10.5603/AIT.a2016.0015. View

4.
Sawicki M, Solek-Pastuszka J, Chamier-Cieminska K, Walecka A, Walecki J, Bohatyrewicz R . Computed Tomography Perfusion is a Useful Adjunct to Computed Tomography Angiography in the Diagnosis of Brain Death. Clin Neuroradiol. 2017; 29(1):101-108. PMC: 6394546. DOI: 10.1007/s00062-017-0631-7. View

5.
Saucha W, Solek-Pastuszka J, Bohatyrewicz R, Knapik P . Apnea test in the determination of brain death in patients treated with extracorporeal membrane oxygenation (ECMO). Anaesthesiol Intensive Ther. 2015; 47(4):368-71. DOI: 10.5603/AIT.2015.0051. View