» Articles » PMID: 30179947

Dual Interlocking Telescopic Rod Provides Effective Tibial Stabilization in Children With Osteogenesis Imperfecta

Overview
Publisher Wolters Kluwer
Specialty Orthopedics
Date 2018 Sep 5
PMID 30179947
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Interlocking telescopic rods for the management of osteogenesis imperfecta (OI)-related long bone fractures are a modification of the Sheffield rod. An interlocking pin anchors the obturator at the distal epiphysis, which spares the distal joint, while a T-piece anchors the sleeve at the proximal epiphysis. However, these devices are associated with some problems, including failure to elongate and difficulty with removal. A dual interlocking telescopic rod (D-ITR), in which the sleeve and the obturator are anchored with interlocking pins, was developed to address these problems.

Questions/purposes: In this study, we compared the D-ITR with an older version of a single interlocking telescopic rod (S-ITR) based on (1) surgery-free survival and rod survival; (2) cessation of rod elongation and elongated length of the rod; and (3) risk of refracture and complications related to the interlocking telescopic system.

Methods: This article compares the D-ITR with the S-ITR using a historically controlled, single-surgeon, retrospective design comparing two implants for the management of fractures in children with OI. Before August 2007, we exclusively used the S-ITR (n = 17 patients, 29 tibiae); from July 2008 until October 2014, we exclusively used the D-ITR (n = 17 patients, 26 tibiae). During the 1-year transition period, we performed five of these procedures (two S-ITR in two patients and three D-ITR in three patients), and implant use was based on availability with our preference being the D-ITR during that time when it was available. The general indications for use of both devices were the same: patients with OI and a tibial fracture who were older than 3 to 4 years of age and whose tibial canals were wide enough to accept an intramedullary rod. Younger patients were treated other ways (generally without surgery) and those with narrower canals with thinner, nonelongating rods or Kirschner wires, as indicated. All patients in both groups were available for followup at a minimum of 2 years (mean ± SD, 9.6 ± 3.0 years in the S-ITR group and 5.3 ± 2.1 years in the D-ITR group) except for one patient in the D-ITR group who died > 1 year after the procedure resulting from reasons unrelated to it. For the between-group comparison, we used only the followup data collected up to the ninth postoperative year in the S-ITR group. The truncated followup period of the S-ITR group was a mean of 5.0 ± 1.6 years. The mean age in the S-ITR group was 7 years (range, 3-12 years) and it was 8 years (range, 3-14 years) in the D-ITR group. There were nine boys and 10 girls in each group. Two orthopaedic surgeons other than the operating surgeon performed chart review to address our three research purposes. Survival analyses were performed using the Kaplan-Meier method. The overall pooled risk of refracture and major complications potentially associated with the interlocking telescopic rod system was compared between the groups.

Results: With the numbers available, there were no differences between the D-ITR and the S-ITR in terms of mean surgery-free survival time (5.7 [95% confidence interval {CI}, 4.5-6.9] versus 5.1 [95% CI, 4.1-6.1]; years; p = 0.653) or mean rod survival time (7.4 [95% CI, 6.4-8.4] versus 6.0 [95% CI, 5.1-6.9] years; p = 0.120). With the numbers available, cessation of elongation (4% in the D-ITR group versus 19% in the S-ITR group; p = 0.112) and elongated length (45.3 ± 24.3 mm in the D-ITR group versus 44.2 ± 22.3 mm in the S-ITR group; p = 0.855) also did not differ between the groups. The pooled proportions of refracture or complications after the index surgery were higher in the S-ITR group (25 tibias [81%]) than in the D-ITR group (15 tibias [54%]; p = 0.049). Eight tibias in the S-ITR group had proximal migration of the sleeve compared with no patients in the D-ITR group (p = 0.005).

Conclusions: In patients with OI, the modified D-ITR provides effective tibial stabilization with similar or better results than the S-ITR design. Anchoring the sleeve at the proximal epiphysis with an interlocking pin provides better anchorage and allows easier removal.

Level Of Evidence: Level III, therapeutic study.

Citing Articles

Complications After Intramedullary Fixation Treatment of Patients With Osteogenesis Imperfecta: Telescopic Versus Non-Telescopic Implants.

Bacaksiz Sr T, Akan Sr I Cureus. 2023; 15(9):e45376.

PMID: 37731684 PMC: 10507367. DOI: 10.7759/cureus.45376.


Which is the best femoral implant in children with osteogenesis imperfecta? a retrospective cohort study of 783 procedures.

Yang H, Li B, Xing C, Gao S, Zhu W, Xiong Y BMC Musculoskelet Disord. 2023; 24(1):110.

PMID: 36759791 PMC: 9909911. DOI: 10.1186/s12891-023-06222-2.


Preliminary Results of Bone Lengthening over Telescopic Titanium Intramedullary Rod.

Mingazov E, Gvozdev N, Popkov A, Journeau P, Popkov D Case Rep Orthop. 2023; 2023:4796006.

PMID: 36756206 PMC: 9902136. DOI: 10.1155/2023/4796006.


Management of Osteogenesis Imperfecta: A Multidisciplinary Comprehensive Approach.

Cho T, Ko J, Kim H, Shin H, Yoo W, Shin C Clin Orthop Surg. 2020; 12(4):417-429.

PMID: 33274017 PMC: 7683189. DOI: 10.4055/cios20060.


The orthopaedic management of long bone deformities in genetically and acquired generalized bone weakening conditions.

Wirth T J Child Orthop. 2019; 13(1):12-21.

PMID: 30838071 PMC: 6376434. DOI: 10.1302/1863-2548.13.180184.


References
1.
Cho T, Choi I, Chung C, Yoo W, Lee K, Lee D . Interlocking telescopic rod for patients with osteogenesis imperfecta. J Bone Joint Surg Am. 2007; 89(5):1028-35. DOI: 10.2106/JBJS.F.00814. View

2.
Sarikaya I, Seker A, Erdal O, Gunay H, Inan M, Guler B . Using a corkscrew-tipped telescopic nail in the treatment of osteogenesis imperfecta: a biomechanical study and preliminary results of 17 consecutive cases. J Pediatr Orthop B. 2018; 28(2):173-178. DOI: 10.1097/BPB.0000000000000537. View

3.
Cho T, Lee K, Oh C, Park M, Yoo W, Choi I . Locking plate placement with unicortical screw fixation adjunctive to intramedullary rodding in long bones of patients with osteogenesis imperfecta. J Bone Joint Surg Am. 2015; 97(9):733-7. DOI: 10.2106/JBJS.N.01185. View

4.
Joseph B, Rebello G, B C . The choice of intramedullary devices for the femur and the tibia in osteogenesis imperfecta. J Pediatr Orthop B. 2005; 14(5):311-9. DOI: 10.1097/01202412-200509000-00001. View

5.
Nicolaou N, Bowe J, Wilkinson J, Fernandes J, Bell M . Use of the Sheffield telescopic intramedullary rod system for the management of osteogenesis imperfecta: clinical outcomes at an average follow-up of nineteen years. J Bone Joint Surg Am. 2011; 93(21):1994-2000. DOI: 10.2106/JBJS.J.01893. View