» Articles » PMID: 30155698

Lower Energy Levels and Iodine-based Material Decomposition Images Increase Pancreatic Ductal Adenocarcinoma Conspicuity on Rapid KV-switching Dual-energy CT

Overview
Publisher Springer
Date 2018 Aug 30
PMID 30155698
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Multidetector computed tomography (MDCT) is used in the diagnosis of pancreatic ductal adenocarcinoma (PDAC), but it may be inadequate in some cases. Tumor detection can be improved using rapid kV-switching dual-energy CT (rsDECT) and iodine maps. Our aim this study is to evaluate tumor conspicuity in PDAC cases using rsDECT and iodine maps.

Methods: Ninety cases with PDAC were evaluated rsDECT. Tumor contrast (HU) differences, tumor size, CNR (contrast-noise ratio), and noise were measured at 70 keV, individual CNR-energy level, and 45 keV, respectively. Quantitative differences in contrast gain ∆70-CNR and ∆CNR-45 were compared. On iodine maps, the iodine concentration measured in the tumor and parenchyma was normalized to the aorta as normalized iodine concentration (NIC) and compared.

Results: The median optimized viewing energy level was 51 keV. The mean ± SD tumor contrast values were 62 ± 20, 115 ± 48, and 152 ± 48 HU (p < 0.001); the largest axial diameters were 36.6 ± 5.1, 37.9 ± 4.2, and 38.3 ± 3.7 mm (p = 0.015); the CNRs were 1.83 ± 0.72, 3.37 ± 0.93, and 2.36 ± 0.56; and the image noise levels were 23.7 ± 6.8, 39.3 ± 11.6, and 59.5 ± 17.2 (p < 0.001) (p < 0.001) for 70 keV, optimized energy level, and 45 keV, respectively. The mean ± SD contrast gain ∆70-CNR was 63 ± 12; and ∆CNR-45 was 31 ± 26 HU (p < 0.001). NIC and NIC values were 0.62 ± 0.03 and 1.36 ± 0.05 mg/mL, respectively (p = 0.004).

Conclusion: The use of low energy levels on rsDECT and iodine maps improves tumor conspicuity. This situation may be help better detection of pancreatic tumors.

Citing Articles

Diagnostic Value of Contrast-Enhanced Dual-Energy Computed Tomography in the Pancreatic Parenchymal and Delayed Phases for Pancreatic Cancer.

Kurita Y, Utsunomiya D, Kubota K, Koyama S, Hasegawa S, Hosono K Tomography. 2024; 10(10):1591-1604.

PMID: 39453034 PMC: 11510840. DOI: 10.3390/tomography10100117.


Monoenergetic reconstructions and iodine density maps for visualization of coronary artery stents using 8-cm dual-layer detector spectral computed tomography: an phantom study.

Chen L, Pan N, Hu B, Li Y, Dong S, Zhou Y Quant Imaging Med Surg. 2024; 14(10):7671-7683.

PMID: 39429615 PMC: 11485354. DOI: 10.21037/qims-24-786.


Photon-counting detector computed tomography: iodine density versus virtual monoenergetic imaging of pancreatic ductal adenocarcinoma.

Alagic Z, Duran C, Suzuki C, Halldorsson K, Svensson-Marcial A, Saeter R Abdom Radiol (NY). 2024; .

PMID: 39400586 DOI: 10.1007/s00261-024-04605-0.


The Usefulness of Low-Kiloelectron Volt Virtual Monochromatic Contrast-Enhanced Computed Tomography with Deep Learning Image Reconstruction Technique in Improving the Delineation of Pancreatic Ductal Adenocarcinoma.

Ichikawa Y, Kanii Y, Yamazaki A, Kobayashi M, Domae K, Nagata M J Imaging Inform Med. 2024; .

PMID: 39136827 DOI: 10.1007/s10278-024-01214-7.


Dual-energy CT with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma.

Liang H, Zhou Y, Zheng Q, Yan G, Liao H, Du S Insights Imaging. 2022; 13(1):153.

PMID: 36153376 PMC: 9509509. DOI: 10.1186/s13244-022-01297-2.