» Articles » PMID: 30154007

Effects of Sodium Hypochlorite Concentration and Temperature on the Cyclic Fatigue Resistance of Heat-treated Nickel-titanium Rotary Instruments

Overview
Journal J Endod
Publisher Elsevier
Specialty Dentistry
Date 2018 Aug 30
PMID 30154007
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: We tested the cyclic fatigue resistance of heat-treated instruments immersed in sodium hypochlorite solution under different concentrations and temperature conditions.

Methods: Based on the irrigating solution's concentration and temperature, 135 ProTaper Gold (PTG; Dentsply Sirona, York, PA) F2 instruments were divided equally into 9 groups of 15. Cyclic fatigue testing was performed by using a block with artificial canals with a curvature angle of 60°, a curvature radius of 5 mm, and a curvature center 5 mm from the instrument tip. The block was fixed inside a water bath of distilled water, 2.5% sodium hypochlorite (NaOCl), or 5.25% NaOCl. The temperature was preset at 25°C, 37°C, or 60°C. The instrument was rotated at 300 rpm until fracturing occurred. The number of cycles to fracture was calculated, and the fragment length was measured. Fractured surfaces were examined via scanning electron microscopy. NCF data were analyzed statistically via Kruskal-Wallis and Mann-Whitney tests. All statistical analyses were performed using SPSS software Version 22 (IBM Corp, Armonk, NY) at a 5% significance level.

Results: The number of cycles to fracture of the PTG F2 was highest in distilled water at 25°C and lowest in 5.25% NaOCl at 60°C. Changing the irrigating solution from distilled water to NaOCl and increasing the surrounding temperature reduced the fatigue resistance.

Conclusions: NaOCl irrigating solution at different concentrations and temperatures influenced the cyclic fatigue resistance of PTG instruments. Future NiTi instrument failure studies should be conducted under simulated body temperature conditions in commonly used irrigating solutions.

Citing Articles

Temperature-Dependent Effects on Cyclic Fatigue Resistance in Three Reciprocating Endodontic Systems: An In Vitro Study.

Salamanca Ramos M, Aranguren J, Malvicini G, De Gregorio C, Bonilla C, Perez A Materials (Basel). 2025; 18(5).

PMID: 40077177 PMC: 11901110. DOI: 10.3390/ma18050952.


Effect of phytic acid on chemical, structural, and mechanical characteristics of nickel-titanium endodontic files.

Samara M, Nassar M, Alqedairi A, Alfawaz H, Jamleh A Sci Rep. 2024; 14(1):20164.

PMID: 39215062 PMC: 11364813. DOI: 10.1038/s41598-024-69828-z.


Surface roughness and cyclic fatigue resistance of a novel shaping system: An in-vitro study.

Ozel B, Barut G, Baser Can E PLoS One. 2024; 19(5):e0302551.

PMID: 38696475 PMC: 11065293. DOI: 10.1371/journal.pone.0302551.


Evaluation of cyclic fatigue behavior of RACE EVO rotary Files: In-vitro comparative study.

Allahem Z, Bendahmash M, Almeaither R, Alfawaz H, Alqedairi A Saudi Dent J. 2024; 36(4):656-660.

PMID: 38690374 PMC: 11056425. DOI: 10.1016/j.sdentj.2024.03.009.


Phase transformation behavior and mechanical properties of HyFlex EDM nickel-titanium endodontic rotary instrument: Evaluation at body temperature.

Kimura S, Ebihara A, Maki K, Kyaw M, Kasuga Y, Omori S J Dent Sci. 2024; 19(2):929-936.

PMID: 38618130 PMC: 11010611. DOI: 10.1016/j.jds.2023.07.039.