Abstract

Three-dimensional (3D) computational aortic models have been established to reproduce aortic diseases such as aortic aneurysm and dissection; however, no such models have been developed to study diabetes mellitus (DM). To characterize biomechanical properties of the human aorta with DM, reconstructed aortic CT images were converted into DICOM format, and imported into the 3D segmentation using Mimics software. This resulted in a 3D reconstruction of the complete aorta, including three branches. We applied a pulsatile blood pressure waveform for the ascending aorta to provide a biomimetic environment using COMSOL Multiphysics software. Hemodynamics were compared between the control and DM models. We observed that mean blood flow velocity, aortic pressure, and von Mises stress values were lower in the DM model than in the control model. Furthermore, the range of aortic movement was lower in the DM model than in the control model, suggesting that the DM aortic wall is more susceptible to rupture. When comparing biomechanical properties in discrete regions of the aorta, all values were higher in the ascending aorta for both control and DM models, corresponding to the location of most aortic lesions. We have developed a compute based that integrates advanced image processing strategies and computational techniques based on finite element method to perform hemodynamics analysis based on CT images. Our study of image-based CFD analysis hopes to provide a better understanding of the relationship between aortic hemodynamic and developing pathophysiology of aortic diseases.

Citing Articles

Approaches to vascular network, blood flow, and metabolite distribution modeling in brain tissue.

Kopylova V, Boronovskiy S, Nartsissov Y Biophys Rev. 2023; 15(5):1335-1350.

PMID: 37974995 PMC: 10643724. DOI: 10.1007/s12551-023-01106-0.


Development of a computational fluid dynamic model to investigate the hemodynamic impact of REBOA.

Renaldo A, Lane M, Shapiro S, Mobin F, Jordan J, Williams T Front Physiol. 2022; 13:1005073.

PMID: 36311232 PMC: 9606623. DOI: 10.3389/fphys.2022.1005073.


Numerical and experimental analyses for the improvement of surface instant decontamination technology through biocidal agent dispersion: Potential of application during pandemic.

Neves P, Oliveira T, Magalhaes T, Dos Reis P, Tofaneli L, Santos A PLoS One. 2021; 16(5):e0251817.

PMID: 34010343 PMC: 8133442. DOI: 10.1371/journal.pone.0251817.


Geometric Analysis of Type B Aortic Dissections Shows Aortic Remodeling After Intervention Using Multilayer Stents.

Costache V, Meekel J, Costache A, Melnic T, Solomon C, Chitic A Materials (Basel). 2020; 13(10).

PMID: 32429089 PMC: 7287707. DOI: 10.3390/ma13102274.


Computational Fluid Simulation of Fibrinogen around Dental Implant Surfaces.

Kitajima H, Hirota M, Iwai T, Hamajima K, Ozawa R, Hayashi Y Int J Mol Sci. 2020; 21(2).

PMID: 31963895 PMC: 7014059. DOI: 10.3390/ijms21020660.

References
1.
Shahcheraghi N, Dwyer H, Cheer A, Barakat A, Rutaganira T . Unsteady and three-dimensional simulation of blood flow in the human aortic arch. J Biomech Eng. 2002; 124(4):378-87. DOI: 10.1115/1.1487357. View

2.
Miyama N, Dua M, Yeung J, Schultz G, Asagami T, Sho E . Hyperglycemia limits experimental aortic aneurysm progression. J Vasc Surg. 2010; 52(4):975-83. PMC: 2987703. DOI: 10.1016/j.jvs.2010.05.086. View

3.
Blauth C, Cosgrove D, WEBB B, Ratliff N, Boylan M, Piedmonte M . Atheroembolism from the ascending aorta. An emerging problem in cardiac surgery. J Thorac Cardiovasc Surg. 1992; 103(6):1104-11; discussion 1111-2. View

4.
le Devehat C, Vimeux M, Khodabandehlou T . Blood rheology in patients with diabetes mellitus. Clin Hemorheol Microcirc. 2004; 30(3-4):297-300. View

5.
Pitocco D, Zaccardi F, Di Stasio E, Romitelli F, Santini S, Zuppi C . Oxidative stress, nitric oxide, and diabetes. Rev Diabet Stud. 2010; 7(1):15-25. PMC: 2923377. DOI: 10.1900/RDS.2010.7.15. View