» Articles » PMID: 30136309

Effect of Cycloplegia on the Measurement of Refractive Error in Chinese Children

Overview
Journal Clin Exp Optom
Specialty Ophthalmology
Date 2018 Aug 24
PMID 30136309
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

Background: To compare the results of cycloplegic and non-cycloplegic refractive error measurement in Chinese children, and to assess the relationship between age and the difference in refractive error measured with and without cycloplegia.

Methods: This was a prospective study that recruited 224 healthy Chinese children at an ophthalmology clinic from November 2016 to February 2017. Refraction before and after cycloplegia were measured using an auto-refractor. Then spherical equivalent M, J , and J were calculated. The enrolled children were allocated into three groups according to M: myopia, emmetropia, and hyperopia. The distribution of the refraction was further analysed by stratifying by age: four to six years, seven to 11 years, and 12 to 16 years.

Results: Mean non-cycloplegic M, J , and J were -1.68 ± 2.00 D, 0.05 ± 0.40 D, and 0.01 ± 0.35 D, while mean cycloplegic M, J , and J were -1.16 ± 2.17 D, 0.02 ± 0.40 D, and -0.01 ± 0.35 D. Significant differences were found between cycloplegic and non-cycloplegic M (p = 0.009), whereas there were no significant differences between cycloplegic and non-cycloplegic J and J (p = 0.486 and p = 0.594, respectively). The differences between cycloplegic and non-cycloplegic M were statistically significant in the four to six years group (p = 0.002) and seven to 11 years group (p = 0.023), whereas there was no significant difference between cycloplegic and non-cycloplegic M in the 12 to 16 years group (p = 0.151). The proportion of myopia decreased from 78.1 per cent before cycloplegia to 71.4 per cent after cycloplegia, while the proportion of hyperopia increased from 12.1 per cent before cycloplegia to 21.4 per cent after cycloplegia.

Conclusion: Non-cycloplegic auto-refraction is found to be inaccurate and not suitable for studies of refractive error in Chinese children.

Citing Articles

Effects of tropicamide and compound tropicamide eye drops on ocular biological parameters and choroid thickness in children.

Xu M, Li N, Liu Y, Chen Y, Xie S, Wang J BMC Ophthalmol. 2025; 25(1):31.

PMID: 39833766 PMC: 11744896. DOI: 10.1186/s12886-025-03872-9.


The relationship between contact lens ultraviolet light transmittance and myopia progression: a large-scale retrospective cohort study.

Okada H, Yoshida M, Takeuchi M, Okada E, Mizuki N Precis Clin Med. 2024; 7(4):pbae022.

PMID: 39444429 PMC: 11497595. DOI: 10.1093/pcmedi/pbae022.


Objective Refraction Status before and after Cycloplegia: From Childhood to Young Adulthood.

Panke K, Jorova M Vision (Basel). 2024; 8(3).

PMID: 39311319 PMC: 11417856. DOI: 10.3390/vision8030051.


Comparison of Self Refraction accuracy with Cycloplegic Subjective Refraction in Young Adults.

Babu L, Kumaran S, Gupta D Niger Med J. 2024; 64(3):365-372.

PMID: 38974062 PMC: 11223018.


The Performance of Spot Photoscreener in 6 to 10 Weeks Infants in China: A Cross-Sectional Study.

Li Y, Li J, Wang H, Du M, Wei L, Su T J Ophthalmol. 2024; 2024:8817530.

PMID: 38765182 PMC: 11102112. DOI: 10.1155/2024/8817530.


References
1.
He X, Zou H, Lu L, Zhao R, Zhao H, Li Q . Axial length/corneal radius ratio: association with refractive state and role on myopia detection combined with visual acuity in Chinese schoolchildren. PLoS One. 2015; 10(2):e0111766. PMC: 4333577. DOI: 10.1371/journal.pone.0111766. View

2.
Hiraoka T, Miyata K, Nakamura Y, Ogata M, Okamoto F, Oshika T . Influence of cycloplegia with topical cyclopentolate on higher-order aberrations in myopic children. Eye (Lond). 2014; 28(5):581-6. PMC: 4017117. DOI: 10.1038/eye.2014.34. View

3.
Hopkins S, Sampson G, Hendicott P, Lacherez P, Wood J . Refraction in children: a comparison of two methods of accommodation control. Optom Vis Sci. 2012; 89(12):1734-9. DOI: 10.1097/OPX.0b013e318277182c. View

4.
Bakaraju R, Fedtke C, Ehrmann K, Falk D, Thomas V, Holden B . Peripheral refraction and higher-order aberrations with cycloplegia and fogging lenses using the BHVI-EyeMapper. J Optom. 2015; 9(1):5-12. PMC: 4705317. DOI: 10.1016/j.optom.2015.06.003. View

5.
Gao L, Zhuo X, Kwok A, Yu N, Ma L, Wang J . The change in ocular refractive components after cycloplegia in children. Jpn J Ophthalmol. 2002; 46(3):293-8. DOI: 10.1016/s0021-5155(02)00479-3. View