» Articles » PMID: 30104926

The Telescoping Hip Plate for Treatment of Femoral Neck Fracture: Design Rationale, Surgical Technique and Early Results

Overview
Journal Iowa Orthop J
Specialty Orthopedics
Date 2018 Aug 15
PMID 30104926
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Recent estimates suggest an annual incidence of greater than 125,000 femoral neck fractures. Surgical treatment is indicated for the majority of these fractures, which are estimated to double by the year 2050. Most displaced femoral neck fractures in elderly patients are treated with arthroplasty secondary to high complication rates associated with internal fixation. Traditional implants used for internal fixation, typically in elderly patients with stable fracture morphology and younger patients regardless of morphology, include the sliding hip screw (SHS), with or without a supplemental anti-rotation screw, and multiple cancellous lag screws. Complications have been reported with both of these fixation techniques, especially as they apply to treating displaced femoral neck fractures in the elderly. Yet, complications of nonunion, loss of fixation and osteonecrosis, among others, still frequently occur in stable patterns of femoral neck fracture treated with internal fixation. Accordingly, additional implants have been designed recently to improve outcomes and avoid such complications in this population. The Targon Femoral Neck Plate (Aesculap, Tuttlinger, Germany) has been used in Europe for the treatment of both displaced and nondisplaced femoral neck fractures by combining a side plate and multiple cancellous lag screws. Multiple studies have shown superior rates of both nonunion and osteonecrosis when compared to the SHS and multiple cancellous screws in both displaced and nondisplaced femoral neck fractures. This article details the design rationale, surgical technique and early postoperative results of a new hybrid implant used for the treatment of both displaced and nondisplaced femoral neck fractures.

Citing Articles

The Oval-like Cross-section of Femoral Neck Isthmus in Three-dimensional Morphological Analysis.

Zhang R, Zhao Y, Su X, Li J, Zhao J, Zhang L Orthop Surg. 2021; 13(1):321-327.

PMID: 33417311 PMC: 7862155. DOI: 10.1111/os.12914.


Three-dimensional morphological analysis of the femoral neck torsion angle-an anatomical study.

Zhang R, Su X, Zhao J, Li J, Zhang L, Tang P J Orthop Surg Res. 2020; 15(1):192.

PMID: 32460899 PMC: 7251911. DOI: 10.1186/s13018-020-01712-8.

References
1.
Conn K, Parker M . Undisplaced intracapsular hip fractures: results of internal fixation in 375 patients. Clin Orthop Relat Res. 2004; (421):249-54. View

2.
Aminian A, Gao F, Fedoriw W, Zhang L, Kalainov D, Merk B . Vertically oriented femoral neck fractures: mechanical analysis of four fixation techniques. J Orthop Trauma. 2007; 21(8):544-8. DOI: 10.1097/BOT.0b013e31814b822e. View

3.
Parker M, Cawley S, Palial V . Internal fixation of intracapsular fractures of the hip using a dynamic locking plate: Two-year follow-up of 320 patients. Bone Joint J. 2013; 95-B(10):1402-5. DOI: 10.1302/0301-620X.95B10.31511. View

4.
Liporace F, Gaines R, Collinge C, Haidukewych G . Results of internal fixation of Pauwels type-3 vertical femoral neck fractures. J Bone Joint Surg Am. 2008; 90(8):1654-9. DOI: 10.2106/JBJS.G.01353. View

5.
Keating J, Grant A, Masson M, Scott N, Forbes J . Randomized comparison of reduction and fixation, bipolar hemiarthroplasty, and total hip arthroplasty. Treatment of displaced intracapsular hip fractures in healthy older patients. J Bone Joint Surg Am. 2006; 88(2):249-60. DOI: 10.2106/JBJS.E.00215. View