» Articles » PMID: 30095992

Multilayer Flow Modulator Enhances Vital Organ Perfusion in Patients with Type B Aortic Dissection

Overview
Authors
Affiliations
Soon will be listed here.
Abstract

Management of aortic dissections (AD) is still challenging, with no universally approved guideline among possible surgical, endovascular, or medical therapies. Approximately 25% of patients with AD suffer postintervention malperfusion syndrome or hemodynamic instability, with the risk of sudden death if left untreated. Part of the issue is that vascular implants may themselves induce flow disturbances that critically impact vital organs. A multilayer mesh construct might obviate the induced flow disturbances, and it is this concept we investigated. We used preintervention and post-multilayer flow modulator implantation (PM) geometries from clinical cases of type B AD. In-house semiautomatic segmentation routines were applied to computed tomography images to reconstruct the lumen. The device was numerically reconstructed and adapted to the PM geometry concentrically fit to the true lumen centerline. We also numerically designed a pseudohealthy case, where the geometry of the aorta was extracted interpolating geometric features of preintervention, postimplantation, and published representative healthy volunteers. Computational fluid dynamics methods were used to study the time-dependent flow patterns, shear stress metrics, and perfusion to vital organs. A three-element Windkessel lumped parameter module was coupled to a finite-volume solver to assign dynamic outlet boundary conditions. Multilayer flow modulator not only significantly reduced false lumen blood flow, eliminated local flow disturbances, and globally regulated wall shear stress distribution but also maintained physiological perfusion to peripheral vital organs. We propose further investigation to focus the management of AD on both modulation of blood flow and restoration of physiologic end-organ perfusion rather than mere restoration of vascular lamina morphology. NEW & NOTEWORTHY The majority of aortic dissection modeling efforts have focused on the maintenance of physiological flow using minimally invasive placed grafts. The multilayer flow modulator is a complex mesh construct of wires, designed to eliminate flow disruptions in the lumen, regulate the physiological wall stresses, and enhance endothelial function and offering the promise of improved perfusion of vital organs. This has never been fully proved or modeled, and these issues we confirmed using a dynamic framework of time-varying arterial waveforms.

Citing Articles

Mechanisms of aortic dissection: From pathological changes to experimental and models.

Rolf-Pissarczyk M, Schussnig R, Fries T, Fleischmann D, Elefteriades J, Humphrey J Prog Mater Sci. 2025; 150.

PMID: 39830801 PMC: 11737592. DOI: 10.1016/j.pmatsci.2024.101363.


Multilayer Stent for Emergency Treatment of Acute Type B Aortic Dissection: A Case Report.

Kremer Diniz B, Sena M, Henrique Lima P Vasc Endovascular Surg. 2023; 58(2):205-208.

PMID: 37530096 PMC: 10756007. DOI: 10.1177/15385744231190448.


Aortic Dissection is Determined by Specific Shape and Hemodynamic Interactions.

Williams J, Marlevi D, Bruse J, Nezami F, Moradi H, Fortunato R Ann Biomed Eng. 2022; 50(12):1771-1786.

PMID: 35943618 PMC: 11262626. DOI: 10.1007/s10439-022-02979-0.


The effect of beta-blockers on hemodynamic parameters in patient-specific blood flow simulations of type-B aortic dissection: a virtual study.

Abazari M, Rafiei D, Soltani M, Alimohammadi M Sci Rep. 2021; 11(1):16058.

PMID: 34362955 PMC: 8346572. DOI: 10.1038/s41598-021-95315-w.


Simulation of Fluid-Structure Interaction in Extracorporeal Membrane Oxygenation Circulatory Support Systems.

Nezami F, Ramezanpour M, Khodaee F, Goffer E, Edelman E, Keller S J Cardiovasc Transl Res. 2021; 15(2):249-257.

PMID: 34128180 PMC: 11694477. DOI: 10.1007/s12265-021-10143-7.


References
1.
Fillinger M, Raghavan M, Marra S, Cronenwett J, Kennedy F . In vivo analysis of mechanical wall stress and abdominal aortic aneurysm rupture risk. J Vasc Surg. 2002; 36(3):589-97. DOI: 10.1067/mva.2002.125478. View

2.
Georgakarakos E, Ioannou C, Papaharilaou Y, Kostas T, Katsamouris A . Computational evaluation of aortic aneurysm rupture risk: what have we learned so far?. J Endovasc Ther. 2011; 18(2):214-25. DOI: 10.1583/10-3244.1. View

3.
Wang X, Li X . Fluid-structure interaction based study on the physiological factors affecting the behaviors of stented and non-stented thoracic aortic aneurysms. J Biomech. 2011; 44(12):2177-84. DOI: 10.1016/j.jbiomech.2011.06.020. View

4.
Kang W, Greenberg R, Mastracci T, Eagleton M, Hernandez A, Pujara A . Endovascular repair of complicated chronic distal aortic dissections: intermediate outcomes and complications. J Thorac Cardiovasc Surg. 2011; 142(5):1074-83. DOI: 10.1016/j.jtcvs.2011.03.008. View

5.
Patel A, Eagle K, Vaishnava P . Acute type B aortic dissection: insights from the International Registry of Acute Aortic Dissection. Ann Cardiothorac Surg. 2014; 3(4):368-74. PMC: 4128929. DOI: 10.3978/j.issn.2225-319X.2014.07.06. View