Purpose: To develop a novel framework for rapid, intrinsic head motion measurement in MRI using FID navigators (FIDnavs) from a multichannel head coil array.

Methods: FIDnavs encode substantial rigid-body motion information; however, current implementations require patient-specific training with external tracking data to extract quantitative positional changes. In this work, a forward model of FIDnav signals was calibrated using simulated movement of a reference image within a model of the spatial coil sensitivities. A FIDnav module was inserted into a nonselective 3D FLASH sequence, and rigid-body motion parameters were retrospectively estimated every readout time using nonlinear optimization to solve the inverse problem posed by the measured FIDnavs. This approach was tested in simulated data and in 7 volunteers, scanned at 3T with a 32-channel head coil array, performing a series of directed motion paradigms.

Results: FIDnav motion estimates achieved mean absolute errors of 0.34 ± 0.49 mm and 0.52 ± 0.61° across all subjects and scans, relative to ground-truth motion measurements provided by an electromagnetic tracking system. Retrospective correction with FIDnav motion estimates resulted in substantial improvements in quantitative image quality metrics across all scans with intentional head motion.

Conclusions: Quantitative rigid-body motion information can be effectively estimated using the proposed FIDnav-based approach, which represents a practical method for retrospective motion compensation in less cooperative patient populations.

Citing Articles

3D deuterium metabolic imaging (DMI) of the human liver at 7 T using low-rank and subspace model-based reconstruction.

Nam K, Gursan A, Lee N, Klomp D, Wijnen J, Prompers J Magn Reson Med. 2024; 93(5):1860-1873.

PMID: 39710859 PMC: 11893041. DOI: 10.1002/mrm.30395.


Motion and magnetic field inhomogeneity correction techniques for chemical exchange saturation transfer (CEST) MRI: A contemporary review.

Simegn G, Sun P, Zhou J, Kim M, Reddy R, Zu Z NMR Biomed. 2024; 38(1):e5294.

PMID: 39532518 PMC: 11606773. DOI: 10.1002/nbm.5294.


Sequence-agnostic motion-correction leveraging efficiently calibrated Pilot Tone signals.

Brackenier Y, Cordero-Grande L, McElroy S, Tomi-Tricot R, Barbaroux H, Bridgen P Magn Reson Med. 2024; 92(5):1881-1897.

PMID: 38860530 PMC: 7617263. DOI: 10.1002/mrm.30161.


Rapid motion estimation and correction using self-encoded FID navigators in 3D radial MRI.

Wallace T, Piccini D, Kober T, Warfield S, Afacan O Magn Reson Med. 2023; 91(3):1057-1066.

PMID: 37929608 PMC: 10843402. DOI: 10.1002/mrm.29899.


Simultaneous multislice EPI prospective motion correction by real-time receiver phase correction and coil sensitivity map interpolation.

Li B, Li N, Wang Z, Balan R, Ernst T Magn Reson Med. 2023; 90(5):1932-1948.

PMID: 37448116 PMC: 10795703. DOI: 10.1002/mrm.29789.


References
1.
Babayeva M, Kober T, Knowles B, Herbst M, Meuli R, Zaitsev M . Accuracy and Precision of Head Motion Information in Multi-Channel Free Induction Decay Navigators for Magnetic Resonance Imaging. IEEE Trans Med Imaging. 2015; 34(9):1879-89. DOI: 10.1109/TMI.2015.2413211. View

2.
Ooi M, Krueger S, Thomas W, Swaminathan S, Brown T . Prospective real-time correction for arbitrary head motion using active markers. Magn Reson Med. 2009; 62(4):943-54. PMC: 3033410. DOI: 10.1002/mrm.22082. View

3.
Zhang T, Cheng J, Chen Y, Nishimura D, Pauly J, Vasanawala S . Robust self-navigated body MRI using dense coil arrays. Magn Reson Med. 2015; 76(1):197-205. PMC: 4732937. DOI: 10.1002/mrm.25858. View

4.
Kober T, Marques J, Gruetter R, Krueger G . Head motion detection using FID navigators. Magn Reson Med. 2011; 66(1):135-43. DOI: 10.1002/mrm.22797. View

5.
Tisdall M, Hess A, Reuter M, Meintjes E, Fischl B, van der Kouwe A . Volumetric navigators for prospective motion correction and selective reacquisition in neuroanatomical MRI. Magn Reson Med. 2012; 68(2):389-99. PMC: 3320676. DOI: 10.1002/mrm.23228. View