» Articles » PMID: 29988237

Early Recurrences During the Blanking Period After Atrial Fibrillation Ablation

Overview
Date 2018 Jul 11
PMID 29988237
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Early recurrences of atrial arrhythmias (ERAA) after ablation are common and predict late recurrences and ablation failure.However,becausea proportion of patients with ERAA will have no subsequent arrhythmias after the blanking period, consensus guidelines recommend against immediate repeat ablation for ERAA episodes occurring during the first 3 months post-ablation. In this review, we summarize the predictors, significance, and treatment of ERAA after AF ablation.

Citing Articles

Wristwatch pulse wave monitoring: assessing daily activity post-catheter ablation for atrial fibrillation.

Nonoguchi N, Soejima K, Katsume Y, Hoshida K, Togashi I, Goda A Eur Heart J Digit Health. 2025; 6(1):96-103.

PMID: 39846064 PMC: 11750189. DOI: 10.1093/ehjdh/ztae091.


Interplay between natriuretic peptides and left atrial mechanics and the relation to recurrence of atrial fibrillation following catheter ablation.

Olsen F, Darkner S, Goetze J, Chen X, Henningsen K, Pehrson S Int J Cardiovasc Imaging. 2023; 39(10):1889-1895.

PMID: 37428246 PMC: 10589158. DOI: 10.1007/s10554-023-02913-y.


3D Atrial Strain for Predicting Recurrence of Atrial Fibrillation after Pulmonary Vein Isolation.

Krizanovic-Grgic I, Anwer S, Steffel J, Hofer D, Saguner A, Spengler C J Clin Med. 2023; 12(11).

PMID: 37297892 PMC: 10253337. DOI: 10.3390/jcm12113696.


Predictive value of TRPV2 expression from peripheral blood mononuclear cells on the early recurrence of atrial fibrillation after radiofrequency catheter ablation.

Ling X, Wang J, Qin X, Lin C, Jie W, Chen Y BMC Cardiovasc Disord. 2022; 22(1):546.

PMID: 36513971 PMC: 9746099. DOI: 10.1186/s12872-022-02992-0.


The atrial fibrillation burden during the blanking period is predictive of time to recurrence after catheter ablation.

Silva Cunha P, Portugal G, Laranjo S, Alves M, Papoila A, Valente B Int J Cardiol Heart Vasc. 2022; 43:101138.

PMID: 36275421 PMC: 9579489. DOI: 10.1016/j.ijcha.2022.101138.


References
1.
Andrade J, Macle L, Khairy P, Khaykin Y, Mantovan R, De Martino G . Incidence and significance of early recurrences associated with different ablation strategies for AF: a STAR-AF substudy. J Cardiovasc Electrophysiol. 2012; 23(12):1295-301. DOI: 10.1111/j.1540-8167.2012.02399.x. View

2.
Mugnai G, de Asmundis C, Hunuk B, Stroker E, Velagic V, Moran D . Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: Predictive role of atrial arrhythmias occurring in the blanking period on the incidence of late recurrences. Heart Rhythm. 2016; 13(4):845-51. DOI: 10.1016/j.hrthm.2015.12.034. View

3.
Lim H, Schultz C, Dang J, Alasady M, Lau D, Brooks A . Time course of inflammation, myocardial injury, and prothrombotic response after radiofrequency catheter ablation for atrial fibrillation. Circ Arrhythm Electrophysiol. 2014; 7(1):83-9. DOI: 10.1161/CIRCEP.113.000876. View

4.
Ciconte G, Baltogiannis G, de Asmundis C, Sieira J, Conte G, di Giovanni G . Circumferential pulmonary vein isolation as index procedure for persistent atrial fibrillation: a comparison between radiofrequency catheter ablation and second-generation cryoballoon ablation. Europace. 2015; 17(4):559-65. DOI: 10.1093/europace/euu350. View

5.
Miyazaki S, Kuroi A, Hachiya H, Nakamura H, Taniguchi H, Ichihara N . Early Recurrence After Pulmonary Vein Isolation of Paroxysmal Atrial Fibrillation With Different Ablation Technologies - Prospective Comparison of Radiofrequency vs. Second-Generation Cryoballoon Ablation. Circ J. 2015; 80(2):346-53. DOI: 10.1253/circj.CJ-15-1051. View