Abstract

The dispersibility and stability issues of peptide drugs during preparation and storage hinder the widespread adoption of pressurized metered-dose inhaler (pMDI). This study aimed to develop a reverse microemulsion (RM) of exenatide (EXE) pMDI through a liquid-based bottom-up method, thus to overcome the stability issue of peptide drugs encountered in traditional top-down methods, such as milling down and high-pressure homogenization. In this study, Pluronic® L64 (L64) was chosen as a surfactant to prepare the EXE-RM pMDI formulations with the assistance of ethanol. The results showed RM possessed a particle size of 123.80 ± 2.91 nm with 0.121 ± 0.024 PdI and a satisfied fine-particle fraction of 41.30 ± 3.73% measured by a next-generation impactor. In addition, the dispersion stability of RM pMDI was maintained after storage at 4 °C for 50 days. The secondary structure of EXE was maintained during the preparation process. Moreover, the results indicated that L64 was compatible with cells and could improve the penetration of EXE through cell monolayers. Through the liquid-based bottom-up method, EXE-RM pMDI was successfully prepared and exhibited favorable stability and aerodynamic performance. This study offers a preparation strategy to enhance the stability of peptides in pMDIs.

Citing Articles

A Pilot Study Exploiting the Industrialization Potential of Solid Lipid Nanoparticle-Based Metered-Dose Inhalers.

Shu L, Wang W, Ng C, Zhang X, Huang Y, Wu C Pharmaceutics. 2023; 15(3).

PMID: 36986727 PMC: 10052976. DOI: 10.3390/pharmaceutics15030866.


Low Drug Loading Hampers the Clinical Translation of Peptide Drugs-Containing Metered-Dose Inhalers.

Huang Z, Shu L, Huang Y, Wu C, Pan X Pharmaceuticals (Basel). 2022; 15(4).

PMID: 35455386 PMC: 9031202. DOI: 10.3390/ph15040389.


Comparison of ELISA and HPLC-MS methods for the determination of exenatide in biological and biotechnology-based formulation matrices.

Pinho A, Fortuna A, Falcao A, Santos A, Seica R, Estevens C J Pharm Anal. 2019; 9(3):143-155.

PMID: 31297291 PMC: 6598173. DOI: 10.1016/j.jpha.2019.02.001.


Drying Technologies for the Stability and Bioavailability of Biopharmaceuticals.

Emami F, Vatanara A, Park E, Na D Pharmaceutics. 2018; 10(3).

PMID: 30126135 PMC: 6161129. DOI: 10.3390/pharmaceutics10030131.