» Articles » PMID: 29915961

Determination of the Surgical Margin in Laparoscopic Liver Resections Using Infrared Indocyanine Green Fluorescence

Overview
Specialty General Surgery
Date 2018 Jun 20
PMID 29915961
Citations 30
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Laparoscopic liver resection is increasingly used to treat patients with hepatic tumor. However, during laparoscopic resection, information obtained by palpation using laparoscopic forceps or from intraoperative ultrasonography is extremely limited, which may pose a risk for positive surgical margins. This study aimed to investigate the feasibility and clinical application of near-infrared (NIR) fluorescence imaging to guide laparoscopic liver resection of a liver tumor and secure the surgical margins.

Methods: A preliminary study in 25 patients was conducted. NIR imaging was used intraoperatively during laparoscopic liver resection. The liver tumors were preoperatively labeled by intravenously injecting the patients with indocyanine green dye (0.5 mg/kg), an NIR fluorescence agent. During the surgical procedure, the PINPOINT Endoscopic Fluorescence Imaging System was used to assess the surgical margin by using real-time endoscopic high-definition visible and NIR fluorescence imaging.

Results: All tumors were identified and resected laparoscopically by using the PINPOINT system, and all resections successfully secured the surgical margin. The pathological findings of all tumors indicated negative margins, defined as R0.

Conclusions: This technique showed the potential to improve the intraoperative identification and demarcation of tumors. Its use could potentially reduce the number of positive resection margins.

Citing Articles

Real-Time Navigation in Liver Surgery Through Indocyanine Green Fluorescence: An Updated Analysis of Worldwide Protocols and Applications.

Avella P, Spiezia S, Rotondo M, Cappuccio M, Scacchi A, Inglese G Cancers (Basel). 2025; 17(5).

PMID: 40075718 PMC: 11898688. DOI: 10.3390/cancers17050872.


Indocyanine green dyed gauze-guided minimum invasive surgery for anatomical landmarks and preventing gauze remnants: a pilot study.

Tashiro Y, Aoki T, Yasunaga H, Ando S Langenbecks Arch Surg. 2025; 410(1):40.

PMID: 39812866 DOI: 10.1007/s00423-024-03592-6.


Efficacy and safety of indocyanine green-fluorescence imaging guided liver resection: a single-arm prospective cohort study.

Gon H, Omiya S, Komatsu S, Yamasaki N, Murakami S, Fukushima K Langenbecks Arch Surg. 2025; 410(1):34.

PMID: 39794665 PMC: 11723889. DOI: 10.1007/s00423-024-03602-7.


Cutting-edge insights: near-infrared imaging for surgical margin assessment in head and neck tumor resection: a systematic review and meta-analysis.

Li K, Yang J, Lian H, Tian Z, Li C, Gao N Quant Imaging Med Surg. 2024; 14(12):8167-8182.

PMID: 39698655 PMC: 11651944. DOI: 10.21037/qims-24-564.


Liver Resection for Hepatocellular Carcinoma: Recent Advances.

Gundavda K, Patkar S, Varty G, Shah N, Velmurugan K, Goel M J Clin Exp Hepatol. 2024; 15(1):102401.

PMID: 39286759 PMC: 11402310. DOI: 10.1016/j.jceh.2024.102401.


References
1.
Jafari M, Wexner S, Martz J, McLemore E, Margolin D, Sherwinter D . Perfusion assessment in laparoscopic left-sided/anterior resection (PILLAR II): a multi-institutional study. J Am Coll Surg. 2014; 220(1):82-92.e1. DOI: 10.1016/j.jamcollsurg.2014.09.015. View

2.
Hibi T, Cherqui D, Geller D, Itano O, Kitagawa Y, Wakabayashi G . Expanding indications and regional diversity in laparoscopic liver resection unveiled by the International Survey on Technical Aspects of Laparoscopic Liver Resection (INSTALL) study. Surg Endosc. 2015; 30(7):2975-83. DOI: 10.1007/s00464-015-4586-y. View

3.
Cahill R, Anderson M, Wang L, Lindsey I, Cunningham C, Mortensen N . Near-infrared (NIR) laparoscopy for intraoperative lymphatic road-mapping and sentinel node identification during definitive surgical resection of early-stage colorectal neoplasia. Surg Endosc. 2011; 26(1):197-204. DOI: 10.1007/s00464-011-1854-3. View

4.
Hamady Z, Lodge J, Welsh F, Toogood G, White A, John T . One-millimeter cancer-free margin is curative for colorectal liver metastases: a propensity score case-match approach. Ann Surg. 2013; 259(3):543-8. DOI: 10.1097/SLA.0b013e3182902b6e. View

5.
Olson E, Jiang T, Aguilera T, Nguyen Q, Ellies L, Scadeng M . Activatable cell penetrating peptides linked to nanoparticles as dual probes for in vivo fluorescence and MR imaging of proteases. Proc Natl Acad Sci U S A. 2010; 107(9):4311-6. PMC: 2840175. DOI: 10.1073/pnas.0910283107. View