Evaluation of Dry Electrodes in Canine Heart Rate Monitoring

Abstract

The functionality of three dry electrocardiogram electrode constructions was evaluated by measuring canine heart rate during four different behaviors: Standing, sitting, lying and walking. The testing was repeated (n = 9) in each of the 36 scenarios with three dogs. Two of the electrodes were constructed with spring-loaded test pins while the third electrode was a molded polymer electrode with Ag/AgCl coating. During the measurement, a specifically designed harness was used to attach the electrodes to the dogs. The performance of the electrodes was evaluated and compared in terms of heartbeat detection coverage. The effect on the respective heart rate coverage was studied by computing the heart rate coverage from the measured electrocardiogram signal using a pattern-matching algorithm to extract the R-peaks and further the beat-to-beat heart rate. The results show that the overall coverage ratios regarding the electrodes varied between 45⁻95% in four different activity modes. The lowest coverage was for lying and walking and the highest was for standing and sitting.

Citing Articles

Applying Noncontact Sensing Technology in the Customized Product Design of Smart Clothes Based on Anthropometry.

Wang I, Chang W, Wu W, Lin B Sensors (Basel). 2021; 21(23).

PMID: 34883982 PMC: 8659875. DOI: 10.3390/s21237978.


Cardiac monitoring of dogs via smartphone mechanocardiography: a feasibility study.

Lahdenoja O, Hurnanen T, Kaisti M, Koskinen J, Tuominen J, Vaha-Heikkila M Biomed Eng Online. 2019; 18(1):47.

PMID: 31014339 PMC: 6480821. DOI: 10.1186/s12938-019-0667-9.

References
1.
von Borell E, Langbein J, Despres G, Hansen S, Leterrier C, Marchant J . Heart rate variability as a measure of autonomic regulation of cardiac activity for assessing stress and welfare in farm animals -- a review. Physiol Behav. 2007; 92(3):293-316. DOI: 10.1016/j.physbeh.2007.01.007. View

2.
Gacsi M, Maros K, Sernkvist S, Farago T, Miklosi A . Human analogue safe haven effect of the owner: behavioural and heart rate response to stressful social stimuli in dogs. PLoS One. 2013; 8(3):e58475. PMC: 3587610. DOI: 10.1371/journal.pone.0058475. View

3.
Fiedler P, Pedrosa P, Griebel S, Fonseca C, Vaz F, Supriyanto E . Novel Multipin Electrode Cap System for Dry Electroencephalography. Brain Topogr. 2015; 28(5):647-656. DOI: 10.1007/s10548-015-0435-5. View

4.
Essner A, Sjostrom R, Ahlgren E, Gustas P, Edge-Hughes L, Zetterberg L . Comparison of Polar® RS800CX heart rate monitor and electrocardiogram for measuring inter-beat intervals in healthy dogs. Physiol Behav. 2014; 138:247-53. DOI: 10.1016/j.physbeh.2014.10.034. View

5.
Essner A, Sjostrom R, Ahlgren E, Lindmark B . Validity and reliability of Polar® RS800CX heart rate monitor, measuring heart rate in dogs during standing position and at trot on a treadmill. Physiol Behav. 2013; 114-115:1-5. DOI: 10.1016/j.physbeh.2013.03.002. View