Diagnostic Accuracy of Point-of-care Natriuretic Peptide Testing for Chronic Heart Failure in Ambulatory Care: Systematic Review and Meta-analysis

Overview
Journal BMJ
Specialty General Medicine
Date 2018 May 23
PMID 29785952
Citations 28
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To assess the diagnostic accuracy of point-of-care natriuretic peptide tests in patients with chronic heart failure, with a focus on the ambulatory care setting.

Design: Systematic review and meta-analysis.

Data Sources: Ovid Medline, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effects, Embase, Health Technology Assessment Database, Science Citation Index, and Conference Proceedings Citation Index until 31 March 2017.

Study Selection: Eligible studies evaluated point-of-care natriuretic peptide testing (B-type natriuretic peptide (BNP) or N terminal fragment pro B-type natriuretic peptide (NTproBNP)) against any relevant reference standard, including echocardiography, clinical examination, or combinations of these, in humans. Studies were excluded if reported data were insufficient to construct 2×2 tables. No language restrictions were applied.

Results: 42 publications of 39 individual studies met the inclusion criteria and 40 publications of 37 studies were included in the analysis. Of the 37 studies, 30 evaluated BNP point-of-care testing and seven evaluated NTproBNP testing. 15 studies were done in ambulatory care settings in populations with a low prevalence of chronic heart failure. Five studies were done in primary care. At thresholds >100 pg/mL, the sensitivity of BNP, measured with the point-of-care index device Triage, was generally high and was 0.95 (95% confidence interval 0.90 to 0.98) at 100 pg/mL. At thresholds <100 pg/mL, sensitivity ranged from 0.46 to 0.97 and specificity from 0.31 to 0.98. Primary care studies that used NTproBNP testing reported a sensitivity of 0.99 (0.57 to 1.00) and specificity of 0.60 (0.44 to 0.74) at 135 pg/mL. No statistically significant difference in diagnostic accuracy was found between point-of-care BNP and NTproBNP tests.

Conclusions: Given the lack of studies in primary care, the paucity of NTproBNP data, and potential methodological limitations in these studies, large scale trials in primary care are needed to assess the role of point-of-care natriuretic peptide testing and clarify appropriate thresholds to improve care of patients with suspected or chronic heart failure.

Citing Articles

Accuracy of brain natriuretic peptide and N-terminal brain natriuretic peptide for detecting paediatric pulmonary hypertension: a systematic review and meta-analysis.

Zhou R, Lei Y, Ge L, Mao Q, Yang L, Qiu X Ann Med. 2024; 56(1):2352603.

PMID: 38753384 PMC: 11100439. DOI: 10.1080/07853890.2024.2352603.


Sendaway capillary NT-proBNP in pulmonary hypertension.

Stubbs H, Cannon J, Knightbridge E, Durrington C, Roddis C, Gin-Sing W BMJ Open Respir Res. 2024; 11(1).

PMID: 38519115 PMC: 10961571. DOI: 10.1136/bmjresp-2023-002124.


Recent successes in heart failure treatment.

Lam C, Docherty K, Ho J, McMurray J, Myhre P, Omland T Nat Med. 2023; 29(10):2424-2437.

PMID: 37814060 DOI: 10.1038/s41591-023-02567-2.


Comparing the Diagnostic Performance of HFA-PEFF and H2FPEF Scoring Systems in Heart Failure with Preserved Ejection Fraction Patients: Insights from the APOLLON Registry.

Mert G, Ozlek B, Ozlek E, Zencirkiran Agus H, Tekinalp M, Kahraman S Anatol J Cardiol. 2023; 27(9):539-548.

PMID: 37655737 PMC: 10510413. DOI: 10.14744/AnatolJCardiol.2023.3345.


2023 National Heart Center/Saudi Heart Association Focused Update of the 2019 Saudi Heart Association Guidelines for the Management of Heart Failure.

Al Habeeb W, Tash A, Elasfar A, Almasood A, Bakhsh A, Elshaer F J Saudi Heart Assoc. 2023; 35(1):71-134.

PMID: 37323135 PMC: 10263126. DOI: 10.37616/2212-5043.1334.


References
1.
Mak G, DeMaria A, Clopton P, Maisel A . Utility of B-natriuretic peptide in the evaluation of left ventricular diastolic function: comparison with tissue Doppler imaging recordings. Am Heart J. 2004; 148(5):895-902. DOI: 10.1016/j.ahj.2004.02.016. View

2.
Zaphiriou A, Robb S, Murray-Thomas T, Mendez G, Fox K, McDonagh T . The diagnostic accuracy of plasma BNP and NTproBNP in patients referred from primary care with suspected heart failure: results of the UK natriuretic peptide study. Eur J Heart Fail. 2005; 7(4):537-41. DOI: 10.1016/j.ejheart.2005.01.022. View

3.
Taylor C, Roalfe A, Iles R, Hobbs F, Barton P, Deeks J . Primary care REFerral for EchocaRdiogram (REFER) in heart failure: a diagnostic accuracy study. Br J Gen Pract. 2016; 67(655):e94-e102. PMC: 5308123. DOI: 10.3399/bjgp16X688393. View

4.
Villacorta H, Duarte A, Duarte N, Carrano A, Mesquita E, Dohmann H . The role of B-type natriuretic peptide in the diagnosis of congestive heart failure in patients presenting to an emergency department with dyspnea. Arq Bras Cardiol. 2003; 79(6):569-72, 564-8. DOI: 10.1590/s0066-782x2002001500002. View

5.
Song F, Khan K, Dinnes J, Sutton A . Asymmetric funnel plots and publication bias in meta-analyses of diagnostic accuracy. Int J Epidemiol. 2002; 31(1):88-95. DOI: 10.1093/ije/31.1.88. View