» Articles » PMID: 29774421

A Fluorometric Aptasensor for Methamphetamine Based on Fluorescence Resonance Energy Transfer Using Cobalt Oxyhydroxide Nanosheets and Carbon Dots

Overview
Journal Mikrochim Acta
Specialties Biotechnology
Chemistry
Date 2018 May 19
PMID 29774421
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Cobalt oxyhydroxide (CoOOH) nanosheets are efficient fluorescence quenchers due to their specific optical properties and high surface area. The combination of CoOOH nanosheets and carbon dots (CDs) has not been used in any aptasensor based on fluorescence quenching so far. An aptamer based fluorometric assay is introduced that is making use of fluorescent CDs conjugated to the aptamer against methamphetamine (MTA), and of CoOOH nanosheets which reduce the fluorescence of the CDs as a quencher. The results revealed that the conjugated CDs with aptamers were able to enclose the CoOOH nanosheets. Consequently, fluorescence is quenched. If the aptamer on the CD binds MTA, the CDs are detached from CoOOH nanosheets. As a result, fluorescence is restored proportionally to zhe MTA concentration. The fluorometric limit of detection is 1 nM with a dynamic range from 5 to 156 nM. The method was validated by comparing the results obtained by the new method to those obtained by ion mobility spectroscopy. Theoretical studies showed that the distance between CoOOH nanosheet and C-Ds is approximately 7.6 Å which can illustrate the possibility of FRET phenomenon. The interactions of MTA and the aptamer were investigated using molecular dynamic simulation (MDS). Graphical abstract Carbon dots (C-Ds) were prepared from grape leaves, conjugated to aptamer, and adsorbed on CoOOH nanosheets. So, the fluorescence of C-Ds is quenched. On addition of MTA, fluorescence is restored.

Citing Articles

An electrochemical aptasensor for methylamphetamine rapid detection by single-on mode based on competition with complementary DNA.

Chang W, Zheng Z, Ma Y, Du Y, Shi X, Wang C Sci Rep. 2024; 14(1):9279.

PMID: 38654039 PMC: 11039698. DOI: 10.1038/s41598-024-59505-6.


Antibody-Conjugated Electrospun Nanofibers for Electrochemical Detection of Methamphetamine.

Atik G, Kilic N, Horzum N, Odaci D, Timur S ACS Appl Mater Interfaces. 2023; 15(20):24109-24119.

PMID: 37184103 PMC: 10214377. DOI: 10.1021/acsami.3c02266.


A Comparative Study of Voltammetric vs Impedimetric Immunosensor for Rapid SARS-CoV-2 Detection at the Point-of-care.

Tortolini C, Angeloni A, Antiochia R Electroanalysis. 2022; .

PMID: 36247366 PMC: 9538619. DOI: 10.1002/elan.202200349.


Nanomaterial-based adsorbents and optical sensors for illicit drug analysis.

Chen C, Wang C, Ko P, Chen Y J Food Drug Anal. 2022; 28(4):654-676.

PMID: 35696141 PMC: 9261814. DOI: 10.38212/2224-6614.1137.


Interpol review of controlled substances 2016-2019.

Jones N, Comparin J Forensic Sci Int Synerg. 2021; 2:608-669.

PMID: 33385148 PMC: 7770462. DOI: 10.1016/j.fsisyn.2020.01.019.


References
1.
Qi Y, Xiu F, Yu G, Huang L, Li B . Simple and rapid chemiluminescence aptasensor for Hg in contaminated samples: A new signal amplification mechanism. Biosens Bioelectron. 2016; 87:439-446. DOI: 10.1016/j.bios.2016.08.022. View

2.
Schuttelkopf A, van Aalten D . PRODRG: a tool for high-throughput crystallography of protein-ligand complexes. Acta Crystallogr D Biol Crystallogr. 2004; 60(Pt 8):1355-63. DOI: 10.1107/S0907444904011679. View

3.
Li G, Kong W, Zhao M, Lu S, Gong P, Chen G . A fluorescence resonance energy transfer (FRET) based "Turn-On" nanofluorescence sensor using a nitrogen-doped carbon dot-hexagonal cobalt oxyhydroxide nanosheet architecture and application to α-glucosidase inhibitor screening. Biosens Bioelectron. 2016; 79:728-35. DOI: 10.1016/j.bios.2015.12.094. View

4.
Hornak V, Abel R, Okur A, Strockbine B, Roitberg A, Simmerling C . Comparison of multiple Amber force fields and development of improved protein backbone parameters. Proteins. 2006; 65(3):712-25. PMC: 4805110. DOI: 10.1002/prot.21123. View

5.
Choudhary R, Patra S, Madhuri R, Sharma P . RETRACTED: Designing of carbon based fluorescent nanosea-urchin via green-synthesis approach for live cell detection of zinc oxide nanoparticle. Biosens Bioelectron. 2017; 91:472-481. DOI: 10.1016/j.bios.2016.12.067. View