» Articles » PMID: 29755211

Microfluidic Diatomite Analytical Devices for Illicit Drug Sensing with Ppb-Level Sensitivity

Overview
Date 2018 May 15
PMID 29755211
Citations 35
Authors
Affiliations
Soon will be listed here.
Abstract

The escalating research interests in porous media microfluidics, such as microfluidic paper-based analytical devices, have fostered a new spectrum of biomedical devices for point-of-care (POC) diagnosis and biosensing. In this paper, we report microfluidic diatomite analytical devices (μDADs), which consist of highly porous photonic crystal biosilica channels, as an innovative lab-on-a-chip platform to detect illicit drugs. The μDADs in this work are fabricated by spin-coating and tape-stripping diatomaceous earth on regular glass slides with cross section of 400×30µm. As the most unique feature, our μDADs can simultaneously perform on-chip chromatography to separate small molecules from complex biofluidic samples and acquire the surface-enhanced Raman scattering spectra of the target chemicals with high specificity. Owing to the ultra-small dimension of the diatomite microfluidic channels and the photonic crystal effect from the fossilized diatom frustules, we demonstrate unprecedented sensitivity down to part-per-billion (ppb) level when detecting pyrene (1ppb) from mixed sample with Raman dye and cocaine (10 ppb) from human plasma. This pioneering work proves the exclusive advantage of μDADs as emerging microfluidic devices for chemical and biomedical sensing, especially for POC drug screening.

Citing Articles

Unveiling the state of the art: a systematic review and meta-analysis of paper-based microfluidic devices.

Garcia-Azuma R, Werner K, Revilla-Monsalve C, Trinidad O, Altamirano-Bustamante N, Altamirano-Bustamante M Front Bioeng Biotechnol. 2024; 12:1421831.

PMID: 39234268 PMC: 11372461. DOI: 10.3389/fbioe.2024.1421831.


Fabrication and Application of Ag@SiO/Au Core-Shell SERS Composite in Detecting Cu in Water Environment.

Zhang M, Meng L, Kalyinur K, Dong S, Chang X, Yu Q Molecules. 2024; 29(7).

PMID: 38611782 PMC: 11013303. DOI: 10.3390/molecules29071503.


Recent reports on the sensing strategy and the On-site detection of illegal drugs.

Zhao Y, Gan Y, Chen J, Zheng H, Chang Y, Lin C RSC Adv. 2024; 14(10):6917-6929.

PMID: 38410368 PMC: 10895702. DOI: 10.1039/d3ra06931a.


Screen Printed Particle-Based Microfluidics: Optimization and Exemplary Application for Heavy Metals Analysis.

Saar I, Evard H Micromachines (Basel). 2023; 14(7).

PMID: 37512680 PMC: 10386728. DOI: 10.3390/mi14071369.


Fabrication of a Floatable Micron-Sized Enzyme Device Using Diatom Frustules.

San Lin N, Hirayama K, Kitamura M, Koide S, Kitajima H, Harada T ACS Omega. 2023; 8(23):21145-21153.

PMID: 37332799 PMC: 10268610. DOI: 10.1021/acsomega.3c02104.


References
1.
Carrilho E, Martinez A, Whitesides G . Understanding wax printing: a simple micropatterning process for paper-based microfluidics. Anal Chem. 2010; 81(16):7091-5. DOI: 10.1021/ac901071p. View

2.
Cheng C, Martinez A, Gong J, Mace C, Phillips S, Carrilho E . Paper-based ELISA. Angew Chem Int Ed Engl. 2010; 49(28):4771-4. DOI: 10.1002/anie.201001005. View

3.
Trewyn B, Giri S, Slowing I, Lin V . Mesoporous silica nanoparticle based controlled release, drug delivery, and biosensor systems. Chem Commun (Camb). 2007; (31):3236-45. DOI: 10.1039/b701744h. View

4.
Brunetto M, Delgado Cayama Y, Gutierrez Garcia L, Gallignani M, Obando M . Determination of cocaine and benzoylecgonine by direct injection of human urine into a column-switching liquid chromatography system with diode-array detection. J Pharm Biomed Anal. 2005; 37(1):115-20. DOI: 10.1016/j.jpba.2004.09.048. View

5.
De Tommasi E, Rea I, Mocella V, Moretti L, De Stefano M, Rendina I . Multi-wavelength study of light transmitted through a single marine centric diatom. Opt Express. 2010; 18(12):12203-12. DOI: 10.1364/OE.18.012203. View