Experimentally Achievable Accuracy Using a Digital Image Correlation Technique in Measuring Small-Magnitude (<0.1%) Homogeneous Strain Fields

Overview
Publisher MDPI
Date 2018 May 9
PMID 29738441
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Measuring small-magnitude strain fields using a digital image correlation (DIC) technique is challenging, due to the noise-signal ratio in strain maps. Here, we determined the level of accuracy achievable in measuring small-magnitude (<0.1%) homogeneous strain fields. We investigated different sets of parameters for image processing and imaging pre-selection, based on single-image noise level. The trueness of DIC was assessed by comparison of Young&rsquo;s modulus (E) and Poisson&rsquo;s ratio (&nu;) with values obtained from strain gauge measurements. Repeatability was improved, on average, by 20⁻25% with experimentally-determined optimal parameters and image pre-selection. Despite this, the intra- and inter-specimen repeatability of strain gauge measurements was 5 and 2.5 times better than DIC, respectively. Moreover, although trueness was also improved, on average, by 30⁻45%, DIC consistently overestimated the two material parameters by 1.8% and 3.2% for E and &nu;, respectively. DIC is a suitable option to measure small-magnitude homogeneous strain fields, bearing in mind the limitations in achievable accuracy.

Citing Articles

Differences between two sequential uncemented stem sizes in total hip arthroplasty: A comparative biomechanical study and potential clinical implications.

Wang K, Kenanidis E, Suleman K, Miodownik M, Avadi M, Horne D SICOT J. 2022; 8:43.

PMID: 36367405 PMC: 9651064. DOI: 10.1051/sicotj/2022043.


Improved virtual extensometer measurement method in complex multi-fracture situation.

Chai J, Ouyang Y, Liu J, Zhang D, Du W, Yang J Sci Rep. 2022; 12(1):6819.

PMID: 35474065 PMC: 9042950. DOI: 10.1038/s41598-022-08393-9.


The impact of stem fixation method on Vancouver Type B1 periprosthetic femoral fracture management.

Wang K, Kenanidis E, Gamie Z, Suleman K, Miodownik M, Avadi M SICOT J. 2022; 8:1.

PMID: 34989673 PMC: 8734436. DOI: 10.1051/sicotj/2021064.


A novel specimen shape for measurement of linear strain fields by means of digital image correlation.

Amraish N, Reisinger A, Pahr D Sci Rep. 2021; 11(1):17515.

PMID: 34471200 PMC: 8410939. DOI: 10.1038/s41598-021-97085-x.


Coupled Thermomechanical Response Measurement of Deformation of Nickel-Based Superalloys Using Full-Field Digital Image Correlation and Infrared Thermography.

Zaba K, Trzepiecinski T, Puchlerska S, Noga P, Balcerzak M Materials (Basel). 2021; 14(9).

PMID: 33922779 PMC: 8122995. DOI: 10.3390/ma14092163.


References
1.
Lionello G, Fognani R, Baleani M, Sudanese A, Toni A . Suturing the myotendinous junction in total hip arthroplasty: A biomechanical comparison of different stitching techniques. Clin Biomech (Bristol). 2015; 30(10):1077-82. DOI: 10.1016/j.clinbiomech.2015.09.003. View

2.
Begonia M, Dallas M, Vizcarra B, Liu Y, Johnson M, Thiagarajan G . Non-contact strain measurement in the mouse forearm loading model using digital image correlation (DIC). Bone. 2015; 81:593-601. PMC: 4640949. DOI: 10.1016/j.bone.2015.09.007. View

3.
Ginebra M, Driessens F, Planell J . Effect of the particle size on the micro and nanostructural features of a calcium phosphate cement: a kinetic analysis. Biomaterials. 2004; 25(17):3453-62. DOI: 10.1016/j.biomaterials.2003.10.049. View

4.
Chow L . Next generation calcium phosphate-based biomaterials. Dent Mater J. 2009; 28(1):1-10. PMC: 2721275. DOI: 10.4012/dmj.28.1. View

5.
Carriero A, Abela L, Pitsillides A, Shefelbine S . Ex vivo determination of bone tissue strains for an in vivo mouse tibial loading model. J Biomech. 2014; 47(10):2490-7. PMC: 4071445. DOI: 10.1016/j.jbiomech.2014.03.035. View