Purpose: To evaluate three different microincisional ab interno trabeculectomy procedures in a porcine eye perfusion model.
Methods: In perfused porcine anterior segments, 90° of trabecular meshwork (TM) was ablated using the Trabectome (T; n = 8), Goniotome (G; n = 8), or Kahook device (K; n = 8). After 24 h, additional 90° of TM was removed. Intraocular pressure (IOP) and outflow facility were measured at 5 and 10 μl/min perfusion to simulate an elevated IOP. Structure and function were assessed with canalograms and histology.
Results: At 5 μl/min infusion rate, T resulted in a greater IOP reduction than G or K from baseline (76.12% decrease versus 48.19% and 47.96%, P = 0.013). IOP reduction between G and K was similar (P = 0.420). Removing another 90° of TM caused an additional IOP reduction only in T and G but not in K. Similarly, T resulted in the largest increase in outflow facility at 5 μl/min compared with G and K (first ablation, 3.41 times increase versus 1.95 and 1.87; second ablation, 4.60 versus 2.50 and 1.74) with similar results at 10 μl/min (first ablation, 3.28 versus 2.29 and 1.90 (P = 0.001); second ablation, 4.10 versus 3.01 and 2.01 (P = 0.001)). Canalograms indicated circumferential flow beyond the ablation endpoints.
Conclusions: T, G, and K significantly increased the outflow facility. In this model, T had a larger effect than G and K.
Arimura S, Iwasaki K, Orii Y, Komori R, Takamura Y, Inatani M Sci Rep. 2023; 13(1):20783.
PMID: 38012358 PMC: 10682418. DOI: 10.1038/s41598-023-48121-5.
VEGF-A-induced changes in distal outflow tract structure and function.
Oltmann J, Morell M, Dakroub M, Verma-Fuehring R, Hillenkamp J, Loewen N Graefes Arch Clin Exp Ophthalmol. 2023; 262(2):537-543.
PMID: 37831170 PMC: 10844149. DOI: 10.1007/s00417-023-06252-5.
Strohmaier C, Wanderer D, Zhang X, Agarwal D, Toomey C, Wahlin K Ophthalmol Glaucoma. 2023; 6(6):570-579.
PMID: 37348815 PMC: 10917462. DOI: 10.1016/j.ogla.2023.06.008.
Coarsened Exact Matching of Excisional to Plasma-ablative Trabeculectomy.
Dakroub M, Verma-Fuehring R, Strzalkowska A, Hillenkamp J, Yousef Y, Loewen N J Curr Glaucoma Pract. 2023; 17(1):9-14.
PMID: 37228309 PMC: 10203335. DOI: 10.5005/jp-journals-10078-1384.
Strohmaier C, McDonnell F, Zhang X, Wanderer D, Stamer W, Weinreb R Invest Ophthalmol Vis Sci. 2023; 64(3):29.
PMID: 36939719 PMC: 10043501. DOI: 10.1167/iovs.64.3.29.