Abstract

Background And Aim: The distinction of intestinal fibrosis from inflammation in Crohn's disease (CD) associated strictures has important therapeutic implications. Ultrasound elastography is useful in evaluating the degree of fibrosis in liver, but there is little evidence whether it can assess fibrosis in the bowel. We determined whether shear-wave elastography (SWE), a novel modification of elastography, quantifying tissue stiffness, could differentiate between inflammatory and fibrotic components in strictures of patients with CD.

Methods: Consecutive CD patients with ileal/ileocolonic strictures who underwent SWE within 1 week to surgical resection were enrolled. The SWE value of the stenotic bowel wall was compared to the grade and severity of fibrosis and inflammation, respectively, in the resected bowel specimen.

Results: Thirty-five patients were enrolled. The mean SWE value of stenotic bowel wall was significantly higher in severe fibrosis (23.0 ± 6.3 Kpa) than that in moderate (17.4 ± 3.8 Kpa) and mild fibrosis (14.4 ± 2.1 Kpa)(P = 0.008). Using 22.55 KPa as the cutoff value in discriminating between mild/moderate and severe fibrosis, the sensitivity and specificity was 69.6 % and 91.7% with an area under the curve (AUC) of 0.822 (P = 0.002). However, no significant difference regarding mean SWE existed among different grades of inflammation. The sensitivity and specificity of bowel vascularization score on conventional ultrasound in differentiating severe inflammation from mild/moderate was 87.5 % and 57.9% with AUC of 0.811 (P = 0.002). Combining SWE and conventional ultrasound (bowel vascularization score), we propose a bowel ultrasound classification of intestinal strictures. A moderate agreement between ultrasound and pathological classification was observed (κ = 0.536, P<0.001).

Conclusions: This pilot study suggests that SWE is feasible and accurate in detecting intestinal fibrosis in patients with CD. After validation, combing SWE and bowel vascularization on conventional ultrasound might be applied to guide a management strategy in CD patients through defining the type of intestinal stricture. 10.1093/ibd/izy115_video1izy115.video15777734754001.

Citing Articles

Real-time shear wave elastography in measuring normal ileocolon intestinal wall stiffness using colonoscopy as reference: A single-center research.

Wang S, Li S, Chen S, Li M, Xie X, Ren M Eur J Radiol Open. 2025; 14:100632.

PMID: 39926296 PMC: 11803870. DOI: 10.1016/j.ejro.2024.100632.


The diagnostic value of two-dimensional ultrasound Su-RADS combined with shear wave elastography for benign and malignant lesions of the gastric wall.

Xue J, Lyu G, Li S BMC Med Imaging. 2024; 24(1):352.

PMID: 39731044 PMC: 11681676. DOI: 10.1186/s12880-024-01530-y.


Elastography as a Discriminator Between Fibrotic and Inflammatory Strictures in Crohn's Disease: A Dead End or Bright Future in Clinical Decision-Making? Critical Review.

Kuczynska M, Zbroja M, Drelich-Zbroja A Diagnostics (Basel). 2024; 14(20).

PMID: 39451622 PMC: 11506928. DOI: 10.3390/diagnostics14202299.


Assessment of perianal fistulizing Crohn's disease activity with endoanal ultrasound: A retrospective cohort study.

Hong N, Liu W, Zhang J, Qian K, Liu J, Ye X World J Gastrointest Surg. 2024; 16(8):2494-2502.

PMID: 39220067 PMC: 11362922. DOI: 10.4240/wjgs.v16.i8.2494.


Multimodal dynamic ultrasound approach as predictor of response in patients with Crohn's disease treated with ustekinumab.

Ainora M, Liguori A, Mignini I, Cintoni M, Galasso L, Laterza L Therap Adv Gastroenterol. 2024; 17:17562848241259289.

PMID: 38912296 PMC: 11193931. DOI: 10.1177/17562848241259289.


References
1.
Dillman J, Stidham R, Higgins P, Moons D, Johnson L, Rubin J . US elastography-derived shear wave velocity helps distinguish acutely inflamed from fibrotic bowel in a Crohn disease animal model. Radiology. 2013; 267(3):757-66. PMC: 10341577. DOI: 10.1148/radiol.13121775. View

2.
Lu C, Gui X, Chen W, Fung T, Novak K, Wilson S . Ultrasound Shear Wave Elastography and Contrast Enhancement: Effective Biomarkers in Crohn's Disease Strictures. Inflamm Bowel Dis. 2017; 23(3):421-430. DOI: 10.1097/MIB.0000000000001020. View

3.
Peyrin-Biroulet L, Harmsen W, Tremaine W, Zinsmeister A, Sandborn W, Loftus Jr E . Surgery in a population-based cohort of Crohn's disease from Olmsted County, Minnesota (1970-2004). Am J Gastroenterol. 2012; 107(11):1693-701. PMC: 3572861. DOI: 10.1038/ajg.2012.298. View

4.
Baumgart D, Muller H, Grittner U, Metzke D, Fischer A, Guckelberger O . US-based Real-time Elastography for the Detection of Fibrotic Gut Tissue in Patients with Stricturing Crohn Disease. Radiology. 2015; 275(3):889-99. DOI: 10.1148/radiol.14141929. View

5.
Berg W, Cosgrove D, Dore C, Schafer F, Svensson W, Hooley R . Shear-wave elastography improves the specificity of breast US: the BE1 multinational study of 939 masses. Radiology. 2012; 262(2):435-49. DOI: 10.1148/radiol.11110640. View